Mechanistic studies on enzymatic reactions by electrospray ionization MS using a capillary mixer with adjustable reaction chamber volume for time-resolved measurements.

نویسندگان

  • Derek J Wilson
  • Lars Konermann
چکیده

Mass spectrometry (MS)-based techniques have enormous potential for kinetic studies on enzyme-catalyzed processes. In particular, the use of electrospray ionization (ESI) MS for steady-state measurements is well established. However, there are very few reports of MS-based studies in the pre-steady-state regime, because it is difficult to achieve the time resolution required for this type of experiment. We have recently developed a capillary mixer with adjustable reaction chamber volume for kinetic studies by ESI-MS with millisecond time resolution (Wilson, D. J.; Konermann, L. Anal. Chem. 2003, 75, 6408-6414). Data can be acquired in kinetic mode, where the concentrations of selected reactive species are monitored as a function of time, or in spectral mode, where entire mass spectra are obtained for selected reaction times. Here, we describe the application of this technique to study the kinetics of enzyme reactions. The hydrolysis of p-nitrophenyl acetate by chymotrypsin was chosen as a simple chromophoric model system. On-line addition of a "makeup solvent" immediately prior to ionization allowed the pre-steady-state accumulation of acetylated chymotrypsin to be monitored. The rate constant for acetylation, as well as the dissociation constant of the enzyme-substrate complex obtained from these data, is in excellent agreement with results obtained by conventional stopped-flow methods. Bradykinin was chosen to illustrate the performance of the ESI-MS-based method with a nonchromophoric substrate. In this case, the unfavorable rate constant ratio for acylation and deacylation of the enzyme precluded measurements in the pre-steady-state regime. Steady-state experiments were carried out to determine the turnover number and the Michaelis constant for bradykinin. The methodologies used in this work open a wide range of possibilities for future ESI-MS-based kinetic assays in enzymology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A capillary mixer with adjustable reaction chamber volume for millisecond time-resolved studies by electrospray mass spectrometry.

A novel continuous-flow apparatus for on-line kinetic studies of (bio)chemical solution-phase processes by electrospray ionization mass spectrometry (ESI-MS) is described. The device is based on two concentric capillaries. Fluid is released from the inner capillary into the intercapillary space, where it mixes with solution flowing through the outer capillary, thus initiating the reaction of in...

متن کامل

Theta-Glass Capillaries in Electrospray Ionization: Rapid Mixing and Short Droplet Lifetimes

Double-barrel wire-in-a-capillary electrospray emitters prepared from theta-glass capillaries were used to mix solutions during the electrospray process. The relative flow rate of each barrel was continuously monitored with internal standards. The complexation reaction of 18-crown-6 and K(+), introduced from opposite barrels, reaches equilibrium during the electrospray process, suggesting that ...

متن کامل

The expanding role of electrospray ionization mass spectrometry for probing reactive intermediates in solution.

Within the past decade, electrospray ionization mass spectrometry (ESI-MS) has rapidly occupied a prominent position for liquid-phase mechanistic studies due to its intrinsic advantages allowing for efficient "fishing" (rapid, sensitive, specific and simultaneous detection/identification) of multiple intermediates and products directly from a "real-world" solution. In this review we attempt to ...

متن کامل

Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry.

A novel fused-droplet electrospray ionization (FD-ESI) source was developed to generate peptide and protein ions. The sample solution was first ultrasonically nebulized to form fine aerosols. The aerosols were then purged into a glass reaction chamber via nitrogen. Charged methanol droplets were continuously generated through electrospraying the acidic methanol solution from a capillary, which ...

متن کامل

Online monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometry.

Online monitoring of the appearance of the intermediates and products during chemical reactions is helpful to understand reaction mechanisms. Various analytical tools including nuclear magnetic resonance spectroscopy, Raman spectroscopy and mass spectrometry (MS) have been employed for the study. MS is one of the most promising means among analytical tools that can provide information of mass-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 76 9  شماره 

صفحات  -

تاریخ انتشار 2004