Bipolar electrocautery: A rodent model of Sunderland third-degree nerve injury.

نویسندگان

  • Arash Moradzadeh
  • Michael J Brenner
  • Elizabeth L Whitlock
  • Alice Y Tong
  • Janina P Luciano
  • Daniel A Hunter
  • Terence M Myckatyn
  • Susan E Mackinnon
چکیده

OBJECTIVE To determine the Sunderland classification of a bipolar electrocautery injury. METHODS Twenty-two rats received crush (a reproducible Sunderland second-degree injury) or bipolar electrocautery injury and were evaluated for functional, histomorphometric, and immunohistochemical recovery at 21 or 42 days. Animal experiments were performed between July 3 and December 12, 2007. Axonal regeneration and end plate reinnervation were evaluated in double transgenic cyan fluorescent protein-conjugated Thy1 and green fluorescent protein-conjugated S100 mice. RESULTS Compared with crush injury, bipolar electrocautery injury caused greater disruption of myelin and neurofilament architecture at the injury site and decreased nerve fiber counts and percentage of neural tissue distal to the injury (P =.007). Complete functional recovery was seen after crush but not bipolar electrocautery injury. Serial live imaging demonstrated axonal regeneration at week 1 after crush and at week 3 after bipolar electrocautery injury. Qualitative assessment of motor end plate reinnervation at 42 days demonstrated complete neuromuscular end plate reinnervation in the crush group and only limited reinnervation in the bipolar electrocautery group. CONCLUSION Bipolar electrocautery injury in a rodent model resulted in a Sunderland third-degree injury, characterized by gradual, incomplete recovery without intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensory neuropathy associated with aggressive cauterization using a bipolar radiofrequency device in primary TKA.

Because significant postoperative blood loss can result in many complications, hemostasis remains a critical part of successful joint replacement outcomes. Advanced techniques, such as electrocautery use after optimally timed tourniquet release, focus on desired patient blood loss outcomes. The purposes of this study were to report the incidence of nerve injury, identify associated risk factors...

متن کامل

Neural outcomes after plasma knife dissection: a pathologic study and clinical correlation.

BACKGROUND The initial aim was to determine the rate of pathologic tissue damage when dissecting the rat sciatic nerve with either bipolar forceps or low-temperature tripolar plasma knife. The second aim was to determine the safety and effectiveness of the plasma knife during parotid surgery. METHODS A prospective, randomized, single-blind study was performed on 40 rat sciatic nerves dissecte...

متن کامل

Concentration-Effect Relationship of Intrapritoneal Administration of 1, 25 (OH) 2-Vitamin D in a Chronic Constriction Model of Neuropathic Pain

Introduction:  Results: These findings revealed the exaggerated responses in the group which received CCI. The group which was treated by 1 μg/kg of 1,25 vit D3 showed a significant reduction in pain behavior. Injection of 1,25 vit D3 did not change the response of animals to the acetone drop and von frey filament. Discussion: Our results showed that antinoceptive effect of 1,25 vit D3 in a rod...

متن کامل

A study of the Complications of Bipolar Electrocautery Tonsillectomy in Patients Admitted to Vali-e-Asr Hospital of Birjand

Introduction: Tonsillectomy is one of the most common surgeries all over the world and is performed by various methods. This study aimed to investigate the complications of bipolar electrocautery method of tonsillectomy. Methods: This cross-sectional study was performed on 234 patients, 114 female and 120 male individuals. The mean age of the patients was 12.2±8.3 (min=3 and max=58.2) years....

متن کامل

Functional and Physical Outcomes following Use of a Flexible CO2 Laser Fiber and Bipolar Electrocautery in Close Proximity to the Rat Sciatic Nerve with Correlation to an In Vitro Thermal Profile Model

This study compared functional and physical collateral damage to a nerve when operating a Codman MALIS Bipolar Electrosurgical System CMC-III or a CO2 laser coupled to a laser, with correlation to an in vitro model of heating profiles created by the devices in thermochromic ink agarose. Functional damage of the rat sciatic nerve after operating the MALIS or CO2 laser at various power settings a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of facial plastic surgery

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 2010