Screening and determination of pesticides in soil using continuous subcritical water extraction and gas chromatography-mass spectrometry.

نویسندگان

  • Pablo Richter
  • Betsabet Sepúlveda
  • Rodrigo Oliva
  • Katia Calderón
  • Rodrigo Seguel
چکیده

In the present work the efficiency of water under subcritical conditions for the extraction of pesticides having a broad spectrum of polarities from soils was evaluated. The pesticides under study were carbofuran, hexachlorobenzene, dimethoate, simazine, atrazine, lindane, diazinon, methylparathion, alachlor, aldrin-R, metholachlor, chlorpyrifos, heptachlor epoxide, dieldrin, endrin, 4,4-DDT and metoxichlor. Optimization studies were carried out using a blank soil (Non-Polluted Soil 1, CLN-1, RTC) and a real soil which were previously spiked with the pesticide mixture and aged for 60 days. A laboratory-made aluminum oven with controlled temperature was used to carry out the leaching process with subcritical water, where it is placed a pre-heater and the extraction cell. The following variables were studied, keeping the pressure controlled about 1200 p.s.i.: the extraction temperature, the time of static and dynamic extraction and the flow-rate of water (1 p.s.i. = 6894.76 Pa). The extraction efficiency of the pesticides increases with the temperature trending to the quantitative extraction at temperatures near to 300 degrees C. After the extraction process, the analytes were transferred quantitatively to 5 ml dichloromethane, before the determination by GC-MS. The results indicate that under the optimized conditions mostly of the analytes are extracted quantitatively in 90 min with recoveries quite similar to those obtained by the standard Soxhlet extraction procedure. Alternatively, by using an extraction time of 25 min, the method can be used as screening for all the pesticides, with recoveries depending on their polarity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Subcritical Water Extraction of Essential Oils from Matricaria Chamomilla L.

Subcritical water extraction (SWE) of essential oil from Matricaria Chamomilla L.  (M. Chamomilla L.) was performed and compared with conventional method including hydro distillation. The percentage of main extracted components of different temperatures (100, 125, 150 and 175 oc) and water flow rates (1, 2 and 4 ml/min) were investigated at 20 bar pressure and 0.50 mm mean particle size in SWE....

متن کامل

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

Multi-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS)

Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket.Me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 994 1-2  شماره 

صفحات  -

تاریخ انتشار 2003