Performance of charged aerosol detection with hydrophilic interaction chromatography.
نویسندگان
چکیده
The performance of the charged aerosol detector (CAD) was investigated using a diverse set of 29 solutes, including acids, bases and neutrals, over a range of mobile phase compositions, particularly with regard to its suitability for use in hydrophilic interaction chromatography (HILIC). Flow injection analysis was employed as a rapid method to study detector performance. CAD response was 'quasi-universal', strong signals were observed for compounds that have low volatility at typical operating (room) temperature. For relatively involatile solutes, response was reasonably independent of solute chemistry, giving variation of 12-18% RSD from buffered 95% ACN (HILIC) to 10% ACN (RP). Somewhat higher response was obtained for basic compared with neutral solutes. For cationic basic solutes, use of anionic reagents of increasing size in the mobile phase (formic, trifluoroacetic and heptafluorobutyric acid) produced somewhat increased detector response, suggesting that salt formation with these reagents is contributory. However, the increase was not stoichiometric, pointing to a complex mechanism. In general, CAD response increased as the concentration of acetonitrile in the mobile phase was increased from highly aqueous (10% ACN) to values typical in the HILIC range (80-95% ACN), with signal to noise ratios about four times higher than those for the RP range. The response of the CAD is non-linear. Equations describing aerosol formation cannot entirely explain the shape of the plots. Limits of detection (determined with a column for solutes of low k) under HILIC conditions were of the order of 1-3ng on column, which compares favourably with other universal detectors. CAD response to inorganic anions allows observation of the independent movement through the column of the cationic and anionic constituents of basic drugs, which appear to be accompanied by mobile phase counterions, even at quite high solute concentrations.
منابع مشابه
Simple Separation and Detection Techniques for the Analysis of Carbohydrates
Carbohydrates are diffi cult to analyze because they are very polar compounds, exhibit similar structural characteristics, and do not have a suitable chromophore. Their analysis is often performed directly using high-performance anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) with a high pH mobile phase. This technique has been approved for use in a variety of offi c...
متن کاملAnalysis of Silicone Oils by High Performance Liquid Chromatography and Charged Aerosol Detection
متن کامل
Determination of Olive Oil Adulteration by Principal Component Analysis with HPLC–Charged Aerosol Detector Data
Overview Purpose: To examine the use of targeted principal component analysis (PCA) with HPLC-charged aerosol detector data as a means of determining adulteration of olive oils. Method: Oil samples were analyzed as both untreated and hydrolyzed, using a C30 HPLC method and charged aerosol detection. PCA results were determined using peak area percent values of the acylglycerides and free fatty ...
متن کاملElectrostatic repulsion hydrophilic interaction chromatography for isocratic separation of charged solutes and selective isolation of phosphopeptides.
If an ion-exchange column is eluted with a predominantly organic mobile phase, then solutes can be retained through hydrophilic interaction even if they have the same charge as the stationary phase. This combination is termed electrostatic repulsion-hydrophilic interaction chromatography (ERLIC). With mixtures of solutes that differ greatly in charge, repulsion effects can be exploited to selec...
متن کاملReview of operating principle and applications of the charged aerosol detector.
Recently a new detection method, based upon aerosol charging (the charged aerosol detector (CAD)) has been introduced as an alternative to evaporative light-scattering detector (ELSD), chemiluminescent nitrogen detector and refractive index detector for detection of non-ultraviolet and weakly ultraviolet active compounds and for UV-absorbing compounds in the absence of standards. The content of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatography. A
دوره 1405 شماره
صفحات -
تاریخ انتشار 2015