Continuous non-contact corneal pachymetry with a high speed reflectometer.

نویسندگان

  • M Böhnke
  • P Chavanne
  • R Gianotti
  • R P Salathé
چکیده

PURPOSE We developed an instrument that permits non-contact, continuous, high speed and high precision monitoring of corneal thickness and tested the stability and reproducibility of measurements made over extended time periods and under various conditions of low surface reflectivity encountered during protracted exposure of the unmoistened corneal surface to ambient air. METHODS The optical pachymeter (basic component of a broad-band, all-fiber Michelson interferometer) was used to monitor changes in the central corneal thickness of enucleated porcine eyes. Measurements were performed on three groups of eight eyes, each with different surface characteristics: intact epithelium, mechanically abraded epithelium, and 90 microm excimer laser keratectomy. Corneal thickness was monitored continuously with values recorded every 2 to 3 minutes for periods up to 1 hour in the absence of surface rinsing. RESULTS The thicknesses of all unmoistened corneas could be monitored with a precision of 1 microm (ascertained using a calibration glass plate and a living human cornea) over the entire observation period. Under ambient air conditions, deturgescence occurred in each case, and ranged from 1 to 5 microm/min. The rate of corneal thinning was fairly constant during the first 15 minutes of monitoring, but was nonlinear thereafter. Corneas with an intact epithelium had the lowest thinning rate with only 10% of the original thickness lost during the course of 1 hour. Deturgescence increased to 25% in corneas that had mechanical removal of the epithelium and to 28.5% in those that had an anterior excimer laser keratectomy, during a similar time-period. CONCLUSION With this new interferometric method, continuous, non-contact measurement of corneal thickness is possible to within a precision of 1 microm for periods up to 1 hour, even under the modified surface conditions after photoablative keratectomy. This device may be useful for on-line monitoring of ablation depths during such procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo pachymetry in normal eyes of rats, mice and rabbits with the optical low coherence reflectometer

The aim of this study was to determine the central corneal thickness (CCT) in living rats, mice and rabbits using a non-contact, high-speed optical low coherence reflectometer (OLCR) mounted on a regular slit lamp. Both eyes of eight male Wistar rats, eight male balb-c mice and eight male Japanese rabbits were measured. Each eye was measured twice (one measurement consists of 20 scans), the ave...

متن کامل

Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis.

AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...

متن کامل

SCIENTIFIC REPORT Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis

Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...

متن کامل

Comparison of central corneal thickness estimated by an ultrasonic pachymeter and non-contact specular microscopy.

Purpose: To compare central corneal thickness (CCT) measurements of healthy individuals obtained with ultrasonic pachymetry (UP) and non-contact specular microscopy (NCSM). Method: In total, 148 eyes of 74 subjects with no ocular or systemic diseases were included in the study. Central corneal thickness measurements of all patients performed with UP and NCCM were compared. Results: A total ...

متن کامل

Measurement of corneal swelling variations without removal of the contact lens during extended wear.

PURPOSE To validate the use of noncontact scanning slit pachymetry and OCT pachymetry measurements without contact lens (CL) removal, to determine corneal swelling variations during extended wear (EW). METHODS Central corneal thickness (CCT) was measured with ultrasonic (US) pachymetry, noncontact scanning slit pachymetry (Orbscan II; Bausch & Lomb, Tampa, FL), and optical coherence tomograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 14 2  شماره 

صفحات  -