Correlation between central corneal thickness, anterior chamber depth, and corneal keratometry as measured by Oculyzer II and WaveLight OB820 in preoperative cataract surgery patients.
نویسندگان
چکیده
PURPOSE To compare and correlate central corneal thickness (CCT), anterior chamber depth (ACD), and keratometric (flat and steep K) measurements using two anterior segment imaging methods, a Scheimpflug camera system (Oculyzer II [Oculus Optikgeräte GmbH]) and a partial coherence biometry system (WaveLight OB820 [Alcon Laboratories Inc]) in eyes undergoing cataract surgery. METHODS Ninety patients (mean age: 66±13 years [range: 32 to 88 years]) underwent preoperative measurement of CCT, ACD, and keratometric measurements by Scheimpflug tomography (Oculyzer II) and optical low coherence reflectometry (WaveLight OB820). Interdevice agreement and correlation between the two techniques were assessed. RESULTS All measurements were highly correlated and showed no clinically significant difference between methods. Mean CCT was 554.21±39.07 μm and 546.59±37.75 μm for the Oculyzer II and WaveLight OB820, respectively (R²=0.9268). Mean ACD was 2.63±0.44 mm and 2.63±0.43 mm for the Oculyzer II and WaveLight OB820, respectively (R(2)=0.9488). The principal meridian keratometric values were also highly correlated. Mean flat K was 42.88±1.50 diopters (D) and 42.96±1.40 D for the Oculyzer II and WaveLight OB820, respectively (R²=0.8741). Mean steep K was 44.08±1.79 D and 44.26±1.95 D for the Oculyzer II and WaveLight OB820, respectively (R(2)=0.9159). CONCLUSIONS Our data show that the Oculyzer II and WaveLight OB820 provide measurements that are in agreement with published values for CCT and ACD in patients. Excellent agreement for CCT and ACD was found between the two devices, as demonstrated by a high degree of correlation and linearity, in addition to minimal bias. Thus, CCT, ACD, and K measurements by these instruments can both be used in clinical preparation, and their agreement is an ensuring precision factor for cataract and refractive surgeons.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملThe Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure
Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...
متن کاملComparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome.
AIM To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-µm-thick corneal flap and to identify the potential factors that affect corneal flap thickness. METHODS A prospective case study was performed on 120 eyes of 60 patients who were divided into two groups for LASIK, each group consisting ...
متن کاملEvaluation of biometry and corneal astigmatism in cataract surgery patients from Central China
BACKGROUND To evaluate the distribution of biometric parameters and corneal astigmatism using the IOLMaster device before phacoemulsification in cataract patients in Central China. METHODS Consecutive cataract patients were recruited at the Central Hospital of Wuhan between January 2015 and June 2016. Ocular axial length (AL), keratometry values, anterior chamber depth (ACD) and horizontal co...
متن کاملEffect of central corneal thickness, corneal curvature, and axial length on applanation tonometry.
OBJECTIVE To evaluate the effect of central corneal thickness (CCT), corneal curvature, and axial length on applanation tonometry in an in vivo study. METHODS In a masked, prospective clinical trial, we examined 125 eyes of 125 patients scheduled for cataract surgery. Corneal curvature was measured by means of keratometry and axial length by A-scan ultrasonography. By cannulating the anterior...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of refractive surgery
دوره 28 12 شماره
صفحات -
تاریخ انتشار 2012