Bipolar Diffusion Encoding with Implicit Spoiling of Undesired Coherence Pathways

نویسنده

  • T. Feiweier
چکیده

Introduction: High-resolution diffusion tensor imaging (DTI) requires both high SNR and good spatial alignment of images acquired with different b-values and diffusion directions. Due to its acquisition speed, diffusion-weighted (DW) single-shot EPI (ss-EPI) is still commonly used, despite the fact that strong gradient pulses used for diffusion encoding in combination with a low pixel bandwidth along the phase-encoding direction result in considerable eddy-current-induced distortions. Using bipolar (twice refocused) diffusion encoding [1] [2], eddy current distortions are effectively reduced as compared to the monopolar Stejskal-Tanner approach [3]. However, additional spoiler gradients required in order to suppress undesired stimulated echo contributions increase TE and correspondingly reduce SNR [4] [5]. Here, we are discussing a new bipolar gradient scheme omitting the need for explicit spoiling and thus allowing for a marked reduction in TE with negligible impact on eddy current suppression efficiency. Theory: A schematic timing diagram of the new bipolar DW ss-EPI sequence is shown in Fig. 1. Assuming a constant amplitude GD of the four diffusion-encoding gradients, MR physics demands that t0 + t1 = t2 + t3 (0 moment refocusing) and that tprep + t0 + t3 + tadc = t1 + t2 (spin-echo condition). By additionally requiring that TE – tprep – tadc – 2 tR = t0 + t1 + t2 + t3 ≡ TD the diffusion encoding efficiency is maximized. Since tprep, tadc, tR and TE are determined by the measurement protocol and sequence implementation details, respectively, these three conditions for the four parameters t0, t1, t2, t3 leave one degree of freedom. In contrast to the original approach which uses this freedom to zero eddy currents with a specific time constant, here we use it to spoil undesired coherence pathways. Besides the desired twice refocused spinecho, the three RF pulses generate three free induction decays, three spin-echoes, a stimulated echo and an anti-stimulated echo. For each undesired coherence pathway, an inequation describing the demand for an accumulated absolute 0 moment larger than the required spoil moment Mspoil can be formulated. It turns out that a solution exists for this set of inequations that simultaneously fulfills the three basic timing conditions stated above. By using t0 = 1/6 (TD – TS), t1 = 1/6 (2 TD + TS), t2 = 1/6 (TD + 2 TS) and t3 = 1/6 (2 TD – 2 TS) with TS = tprep + tadc, signal contributions of undesired coherences are effectively suppressed if |GD| t0 ≥ Mspoil. Methods: Phantom experiments were performed on a 1.5T whole body MR scanner (MAGNETOM Espree, Siemens Healthcare Sector, Erlangen, Germany) with a 12-element Head Matrix coil. DW images were acquired with a prototype sequence using the standard bipolar timing, the new timing discussed here and a monopolar encoding module: FOV = 256x256 mm, partial Fourier = 6/8, phase-encoding direction A-P, isotropic resolution 2mm, iPAT factor 2 (GRAPPA reconstruction), 25 slices without gap, DW with b = 1000 s/mm, 20 directions, TR = 3500ms, TE = 90ms (standard bipolar), 82ms (new bipolar) and 84ms (monopolar), respectively. Residual eddy current contributions of the diffusion encoding gradients were simulated for all variants assuming a mono-exponential decay using MatLab (The MathWorks Inc., Natick, MA). Results and Discussion: Standard deviation maps are used to assess the spatial alignment of the DW images acquired using different diffusion directions. Residual eddy current induced distortions show up as bright contours in this representation. As shown in Fig. 2a, both standard and new bipolar diffusion-encoding yield similar results, indicating comparable eddy current suppression efficiency. This observation is supported by the simulation results shown in Fig. 2b. The new timing allows reducing TE by 8ms for this protocol, accompanied by a corresponding SNR increase. Conclusion: The proposed modification of the bipolar diffusion encoding scheme allows for a markedly reduced TE and correspondingly increased SNR with negligible impact on eddy current suppression efficiency. First volunteer images confirm the expected benefit, giving prospect of improved DTI data quality. References: [1] Heid: Proceedings ISMRM 2000 p.799, [2] Reese et al.: MRM 49:177 (2003), [3] Stejskal et al.: J.Chem.Phys. 42:288 (1965), [4] Zwanger: US Patent 7,633,291 B2, [5] Morelli et al.: Investigative Radiology 45:29 (2010) Acknowledgement: The author acknowledges helpful discussions with D. Porter. Fig 2: (top) Standard deviation maps of DW images acquired with monopolar (left), new (middle) and standard (right) bipolar diffusion encoding. Note the absence of contour artefacts indicating residual eddy currents for both bipolar schemes as compared to monopolar (white arrow). Simulation results of the residual eddy current amplitude depending on decay time constant and time within echo train (bottom).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole heart DTI using asymmetric bipolar diffusion gradients

Background Cardiac diffusion weighted imaging (DWI) using a spin echo sequence is challenging because of its high sensitivity to bulk motion. When the displacement or acceleration are constant and coherent but not equal for all spins within a voxel, it will cause signal attenuation due intra voxel de-phasing as an effect of first or second order moment encoding errors. This signal attenuation c...

متن کامل

Genes Encoding GABA-β and HT1D Receptors in Bipolar I (Manic Phase) Patients

Introduction: According to the cumulative evidence, genes encoding GABA receptors inhibit neurotransmitters in CNS and are intricately involved in the pathogenesis of mood disorders. Based on this hypothesis, these genes may be expressed in bipolar patients. As a result, we evaluated the gene expressions of GABA-β3 and HT1D receptors to assess their associations with bipolar mood disorder....

متن کامل

An Implicit Difference-ADI Method for the Two-dimensional Space-time Fractional Diffusion Equation

Fractional order diffusion equations are generalizations of classical diffusion equations which are used to model in physics, finance, engineering, etc. In this paper we present an implicit difference approximation by using the alternating directions implicit (ADI) approach to solve the two-dimensional space-time fractional diffusion equation (2DSTFDE) on a finite domain. Consistency, unconditi...

متن کامل

The streamline diffusion method with implicit integration for the multi-dimensional Fermi Pencil Beam equation

We derive error estimates in the appropriate norms, for the streamlinediffusion (SD) finite element methods for steady state, energy dependent,Fermi equation in three space dimensions. These estimates yield optimal convergencerates due to the maximal available regularity of the exact solution.High order SD method together with implicit integration are used. The formulationis strongly consistent...

متن کامل

سوگیری حافظه ناآشکار و آشکار در افراد افسرده بر اساس پردازش انتقال مناسب

The aim of the present research was to examine implicit and explicit memory bias in depressed individuals based on the Transfer Appropriate Processing (TAP) framework. For this purpose, 60 participants (30 outpatient depressed participants for the experimental group and 30 non-depressed participants for the control group) were selected as research sample based on psychiatric interviews of DSM-I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010