Calibration and field evaluation of the Chemcatcher® passive sampler for monitoring metaldehyde in surface water.
نویسندگان
چکیده
Metaldehyde is a potent molluscicide. It is the active ingredient in most slug pellets used for crop protection. This polar compound is considered an emerging pollutant. Due to its environmental mobility, metaldehyde is frequently detected at impacted riverine sites, often at concentrations above the EU Drinking Water Directive limit of 0.1µgL-1 for an individual pesticide. This presents a problem when such waters are abstracted for use in the production of potable water supplies, as this chemical is difficult to remove using conventional treatment processes. Understanding the sources, transport and fate of this pollutant in river catchments is therefore important. We developed a new variant of the Chemcatcher® passive sampler for monitoring metaldehyde comprising a Horizon Atlantic™ HLB-L disk as the receiving phase overlaid with a polyethersulphone membrane. The sampler uptake rate (Rs) was measured in semi-static laboratory (Rs = 15.7mLday-1) and in-field (Rs = 17.8mLday-1) calibration experiments. Uptake of metaldehyde was linear over a two-week period, with no measurable lag phase. Field trials (five consecutive 14day periods) using the Chemcatcher® were undertaken in eastern England at three riverine sites (4th September-12th November 2015) known to be impacted by the seasonal agricultural use of metaldehyde. Spot samples of water were collected regularly during the deployments, with concentrations of metaldehyde varying widely (~ 0.03-2.90µgL-1) and often exceeding the regulatory limit. Time weighted average concentrations obtained using the Chemcatcher® increased over the duration of the trial corresponding to increasing stochastic inputs of metaldehyde into the catchment. Monitoring data obtained from these devices gives complementary information to that obtained by the use of infrequent spot sampling procedures. This information can be used to develop risk assessments and catchment management plans and to assess the effectiveness of any mitigation and remediation strategies.
منابع مشابه
Field performance of the Chemcatcher passive sampler for monitoring hydrophobic organic pollutants in surface water.
Six field trials were carried out to assess the performance of the Chemcatcher passive sampler alongside spot sampling for monitoring priority hydrophobic organic pollutants (polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides) in a wide range of conditions in surface water. The trials were performed in three European rivers: Elbe (Czech Republic), Alna (Norway) and Meuse (Net...
متن کاملEffect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers.
Monitoring of harmful substances in an aquatic environment is based on spot sampling which is the only sampling technique accepted by environmental authorities in the European Union. Still the implementation of the European Union Water Framework Directive (WFD) requires novel sampling tools for monitoring priority pollutants since their concentrations in natural waters can often remain below th...
متن کاملCalibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water.
Triolein embedded cellulose acetate membrane (TECAM) passive samplers provide potentially powerful tool for monitoring time weighted average concentrations (C(TWA)) of trace hydrophobic organic contaminants in water. To study the field performance of TECAM, exchange kinetics of chemicals between water and TECAM were studied at different temperature and water flow rates. Results showed that the ...
متن کاملEvaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrations.
Passive sampling devices accumulate chemicals continuously from water and can provide time weighted average (TWA) concentrations of pollutants over the exposure period. Hence, they offer a number of advantages over other conventional monitoring techniques such as spot or grab sampling. The diffusive gradient in thin film (DGT) and the Chemcatcher passive samplers can be used to provide TWA conc...
متن کاملCharacterization and Application of Passive Samplers for Monitoring of Pesticides in Water.
Five different water passive samplers were calibrated under laboratory conditions for measurement of 124 legacy and current used pesticides. This study provides a protocol for the passive sampler preparation, calibration, extraction method and instrumental analysis. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for silicone rubber, polar organic chem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 179 شماره
صفحات -
تاریخ انتشار 2018