On the influence of core laminations upon power transformer noise

نویسندگان

  • Ravish S. Masti
  • Wim Desmet
  • Ward Heylen
چکیده

Power transformers can be sources of disturbing and annoying acoustic noise. This paper is a first phase report of a wider framework of study that investigates the noise radiation characteristics of air-cooled power transformers. The dynamics of the transformer core structure plays a significant role in the noise generation process. The reported work focuses on the influence of lamination of the core block on its structural dynamic behaviour. The degree of lamination of a core and its boundary conditions have been found to have a strong influence on its resonant behaviour and the need for an accurate modelling of these physical details has been observed through a combined experimental – numerical study. 1. Transformer noise – an annoying disturbance Power transformers are designed for the transmission and distribution of electrical power. Apart from satisfying this functional performance objective, the operation of a transformer happens to induce some annoying acoustic radiation. The requirement for more electrical power associated with the growing density of population, especially in urban areas, has resulted in enhancing the supply capacity of local electrical substations by adding more transformers, or building new substations of high power ratings closer to the neighbourhoods. This may result in the inhabitants in the vicinity being exposed to increased, and often disturbing, noise levels. Transformer acoustic noise is a hum characterised by spectral spikes at harmonics of the fundamental frequency (100 Hz /120 Hz) which is twice the line supply frequency. The transformer’s low frequency tonal noise components are the major source of annoyance and intrusion, invoking noise complaints from the residents, [1, 2]. A growing awareness and concern about public health problems due to noise pollution has brought transformer substations under the purview of tough regulations on excessive noise emission. Therefore, the need for compliance to stricter noise control regulations requires the construction of transformers that are less noise-prone and the design of efficient passive/active control systems for onsite noise control measures. For this purpose, a proper understanding of the noise generation in a transformer and an accurate estimation of its radiation characteristics are necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the Parameters of Disk Winding on the Impulse Voltage Distribution in Power Transformers

Overvoltage distribution along the transformer winding must be uniform to certify the safety of the operation of the power transformer. Influence of the parameters variation on the impulse voltage distribution (IVD) in disk winding transformer is going to be analyzed which hasn’t been analyzed on this type of winding in the previous papers. In this research, a transformer with disk winding and ...

متن کامل

Cost optimization for the slitting of core laminations for power transformers

The successful realization of a project for slitting core laminations for power transformers under minimizing costs is presented. The production of the core of power transformers requires great amounts of grain oriented silicon steel (up to 200 tons for a single transformer). The shape of the cross section of the core is approximated to a circle by stacking sheets of diierent widths. To supply ...

متن کامل

Determination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

متن کامل

Determination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

متن کامل

Impacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect

this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004