Elimination of Inflow Enhancement by Partial Pre-Saturation in RF Spoiled Imaging

نویسندگان

  • M. Han
  • B. A. Hargreaves
چکیده

Introduction: For RF-spoiled gradient echo imaging (ie SPGR, FLASH, T1-FFE), the combination of spoiling gradients and quadratic phase cycling eliminates net transverse magnetization within a voxel [1-4] to enable pure T1 contrast. Generally, many RF excitations are required to attain steady state magnetization levels. Therefore, when unsaturated spins are flowing into the imaging volume, inflow enhancement [5] occurs at entry slices of the slab, which can affect quantitative imaging such as in calculation of the arterial input function. We hypothesize that partial saturation of an outer slab could provide the desired longitudinal magnetization to avoid inflow effects with minimal artifacts. To test this, we investigate the complex magnetization of partially saturated flowing spins in an RF-spoiled gradient echo sequence using simulations, phantom and in vivo experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of ramped RF excitation pulses with built-in out of slab saturation for 3D - TOF angiography

INTRODUCTION – In clinical practice, imaging of the intracranial arteries, such as the Circle of Willis (CoW), is performed most frequently with 3D TOF angiography. This noninvasive technique uses a T1-weighted RF-spoiled gradient echo (SPGR) sequence, typically in conjuction with multiple overlapping slabs (MOTSA) and RF slab excitation pulses with ramped excitation profile (TONE) to reduce bl...

متن کامل

Flow quantification in the heart chambers: 3D PC-SSFP compared with spoiled GE

Introduction: Flow quantification through the valves is of major importance in patients with valvular heart disease. Using a 3D MRI acquisition, the mitral valve can be imaged during the whole cardiac cycle, for direct quantification of flow through the valve. So far, 3D phase contrast (PC) for velocity quantification is only implemented in a spoiled Gradient Echo (GE) sequence. However, PC-GE ...

متن کامل

Investigation of Readout RF Pulse Impact on the Chemical Exchange Saturation Transfer Spectrum

Chemical exchange saturation transfer magnetic resonance imaging (CEST-MRI) is capable of both microenvironment and molecular imaging. The optimization of scanning parameters is important since the CEST effect is sensitive to factors such as saturation power and field homogeneity. The aim of this study was to determine if the CEST effect would be altered by changing the length of readout RF pul...

متن کامل

3D Time-of-Flight MRA Using Inversion Recovery TrueFISP

A major drawback of 3D time-of-flight (TOF) sequences is progressive saturation of inflowing spins along the slab direction, and a sufficient long TR or shaped excitation pulses are required to compensate for this. Here we present a new TOF technique based on a combination of selective inversion and 3D acquisition with TrueFISP. The stationary tissue is partially suppressed by the inversion pul...

متن کامل

Spoiling of transverse magnetization in gradient-echo (GRE) imaging during the approach to steady state.

The signal evolution behaviors and corresponding image appearances for different methods of spoiling or refocusing the transverse magnetization in short TR gradient-echo imaging during the approach to steady state were investigated experimentally and using computer simulations based on the Bloch equations. Specifically, ideally spoiled, gradient-spoiled, gradient-refocused, and RF-spoiled pulse...