Low output, low gradient aortic stenosis.

نویسندگان

  • P MacCarthy
  • A Berger
  • B de Bruyne
چکیده

T his picture shows the chest of a 51 year old man recently admitted to a district general hospital where a diagnosis of myocardial infarction was made. The patient received thrombolysis in the form of streptokinase and subsequently underwent angioplasty and stenting of his right coronary artery. He was informed that the use of streptokinase should not be repeated. Concerned that he would forget to convey this information with any subsequent event he elected to have this tattoo inscribed on his chest. An allergy to some metals had prevented him for opting for a medical alert type of warning bracelet or necklace. This case illustrates that some patients will go to extreme lengths to follow the advice given by their doctors. Low output, low gradient aortic stenosis W e recently investigated a 47 year old man with increasing dyspnoea of effort (New York Heart Association functional class IV) who had undergone homograft aortic valve replacement seven years previously. At cardiac catheterisation, the epicardial coronary arteries were angio-graphically normal. The left ventricle was dilated (end diastolic volume index 134 ml/m 2) and the ejection fraction severely reduced (28%). At baseline, the mean transvalvar aortic gradient at rest was 26 mm Hg and the calculated aortic valve area was 0.77 cm 2 , with a ther-modilution cardiac output of 3.8 l/min. With dobutamine challenge (15 µg/kg/ min) the gradient increased to 58 mm Hg, the cardiac output increased to 8.6 l/min, and the aortic valve area to 1.1 cm 2 (see fig). Despite this significant increase in valve area, this patient was found at surgery to have severe aortic stenosis. Traditionally, an increase in aortic valve area on dobutamine challenge is thought to indicate aortic " pseudosteno-sis " , an artefactually low value at rest being caused by poor cardiac output and inadequate valve cusp opening. The current case illustrates the importance of interpreting changes in valve area, valve gradient, and cardiac output together. Patients with true severe aortic stenosis may comprise a spectrum, from those with good contractile reserve who are able to increase cardiac output (and thus, to a certain extent, aortic valve area) with dobutamine, to those with diminished contractile reserve unable to respond in this way. Pathophysiologi-cally, the left ventricular impairment in the former group may be due more to afterload mismatch and thus respond more favourably to aortic valve replacement than the latter group, who are likely …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-output, low-gradient aortic stenosis in patients with depressed left ventricular systolic function: the clinical utility of the dobutamine challenge in the catheterization laboratory.

BACKGROUND Although aortic valve replacement can be performed at an acceptable risk level in selected patients with left ventricular systolic dysfunction and low-output, low-gradient aortic stenosis, not all patients presenting with these hemodynamics will benefit from the operation. Some patients may have only mild aortic stenosis, despite a small calculated valve area. We report on the clinic...

متن کامل

Letter by Poullis and Warwick regarding article, "Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival".

“Paradoxical Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Preserved Ejection Fraction Is Associated With Higher Afterload and Reduced Survival” To the Editor: In their article, Hachicha et al1 raise a number of key points that merit further questioning. Despite the direct relevance of their findings to everyday clinical practice, it is our opinion that their use of the terms paradoxica...

متن کامل

Paradoxical Low-Flow, Low-Gradient Aortic Stenosis

Low-flow, low-gradient aortic stenosis (AS) is a highly challenging condition in terms of diagnosis and therapeutic management. The transvalvular pressure gradient is inversely related to the square of aortic valve area (AVA) and directly related to the square of flow. Hence, a patient with severe AS may nonetheless present with a low gradient if his or her left ventricular (LV) output is reduc...

متن کامل

Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival.

BACKGROUND Recent studies and current clinical observations suggest that some patients with severe aortic stenosis on the basis of aortic valve area may paradoxically have a relatively low gradient despite the presence of a preserved left ventricular (LV) ejection fraction. The objective of the present study was to document the prevalence, potential mechanisms, and clinical relevance of this ph...

متن کامل

Outcome of patients with low-gradient "severe" aortic stenosis and preserved ejection fraction.

BACKGROUND Retrospective studies have suggested that patients with a low transvalvular gradient in the presence of an aortic valve area < 1.0 cm² and normal ejection fraction may represent a subgroup with an advanced stage of aortic valve disease, reduced stroke volume, and poor prognosis requiring early surgery. We therefore evaluated the outcome of patients with low-gradient "severe" stenosis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart

دوره 89 5  شماره 

صفحات  -

تاریخ انتشار 2003