Accuracy of Combined Anteversion in the Combined Anteversion Technique with Image-free Navigated Total Hip Arthroplasty

نویسندگان

  • Shigeo Fukunishi
  • Yuki Fujihara
  • Shinichi Yoshiya
چکیده

In recent literatures dealing with optimization of prosthetic alignment in total hip arthroplasty (THA), the concept of combined anteversion (CA), which is the sum of acetabular anteversion (AV) and femoral antetorsion (AT), has been addressed. Widmer attempted to determine the optimal CA using a computer simulation study . He proposed the “new safe zone” for the CA value to achieve essential range of motion while avoiding prosthetic impingement. On the other hand, Dorr described the combined anteversion technique (CA technique) to determine both cup and stem alignment during THA procedure . He proposed the so-called “stem-first” procedure for the CA technique in which the stem is set first, and cup alignment is determined to consider the target CA value. In our recent clinical practice, we have been using an image-free THA navigation system (OrthoPilot THA Pro; B/BRAUNAesculap, Germany) to achieve improved overall alignment with both stem and cup . In the present study, the femur was prepared first with the target angle corresponding to the native femoral AT, and the cup AV was decided considering the CA calculated with Widmer’s formula (37.3°= cup AV + 0.7 stem AT) using an image-free navigation system.The purpose of this study was to evaluate the accuracy of CA by using the CA technique with image-free navigated THA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The combined anteversion technique for acetabular component anteversion.

The combined anteversion technique for acetabular component placement of total hip arthroplasty is beneficial because of the surgeons' limited ability to control the anteversion of a cementless femoral stem. Our data show that the cementless stem anteversion can be 15 degrees different than anticipated. By determining femoral stem anteversion before positioning cup anteversion, the cup antevers...

متن کامل

Combined anteversion of the total hip arthroplasty implanted with image-free cup navigation and without stem navigation

In total hip arthroplasty (THA), combined anteversion (CA), the sum of cup anteversion (AV) and stem antetorsion (AT) are used as parameters to assess the appropriateness of overall prosthetic alignment. In this study, we evaluated the CA value based on the post-operative computed tomography (CT) measurements in our patient population who underwent THA using the OrthoPilot™ image-free navigatio...

متن کامل

Direct Anterior Approach Using Navigation Improves Accuracy of Cup Position Compared to Conventional Posterior Approach

The accuracy of cup position in total hip arthroplasty is essential for a satisfactory result as malpositioning increases the risk of complications including dislocation, high wear rate, loosening, squeaking, edge loading, impingement and ultimately failure. We studied 166 patients in a single-surgeon-series of matched cohorts of patients who underwent total hip arthroplasties. Four separate gr...

متن کامل

Adjusting the combined anteversion to maximize range of motion in total hip arthroplasty: Acetabular side or femoral side, which adjustment is more effective?

INTRODUCTION: Cup and stem positioning correlates each other in total hip arthroplasty (THA), and it is believed that optimal combined anteversion (CA), which is a sum of cup and stem anteversion (AV) angle, is about 40° – 60°. However, there are few studies that have compared which adjustment is more effective, changing a cup or a femoral stem to optimizing CA and increasing ROM. In this study...

متن کامل

Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial

Background: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and hasproven to be different from targeted values. This study aims to determine the accuracy of a novel technique using adigital protractor and a spirit level to improve surgeons’ estimation of stem anteversion.Methods: A prospective non-randomized study was conducted a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015