Nasogastric tube malposition leading to a ventilator leak: A case report

نویسنده

  • Anish Singh
چکیده

Journal of Anaesthesia and Critical Care Case Reports 2016 May-Aug;2(2):13-15 Department of anesthesiology, Max Superspeciality Hospital, I.P Extension, Patparganj, New Delhi, India. Address of Correspondence

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Esophageal Perforation Due to Nasogastric Tube Insertion: A Case Report

Introduction: A Nasogastric (NG) tube insertion is a common technique in all neonatal intensive care units (NICUs). In some cases, NG insertion in infants with friable esophageal tissues may lead to some adverse side-effects, although such problems are not commonly seen. Esophageal perforation is a rare but known complication associated with this procedure. Methods: An infant (first child), we...

متن کامل

Secondary Esophagus Perforation caused by Insertion of Nasogastric Tube: A Case Report

  Nasogastric tube (NG) insertion is a usual technique in any neonatal intensive care unit. This procedure is undertaken for the children who are in need of invasive care. Sometimes, the insertion of nasogastric tube in infants with esophagus friable anatomy tissues may have some dangerous side effect, but such problems are not very common. Esophageal perforation is a rare but known compli...

متن کامل

Routine Change of Nasogastric Tube in Intensive Care Unit: Friend or Foe

Dear Editor, Early enteral feeding is a standard of care in many intensive care units (ICU) around the world. The use of enteral route is facilitated by the development of highly flexible nasogastric tubes (NGT). Although the insertion of nasogastric tubes has been described as being easy, but can produce unexpected complications.The insertion of a feeding tube into the lower airway is an uncom...

متن کامل

Ventilator autocycling due to an endotracheal tube cuff leak.

Ventilator autocycling can occur with any ventilator if the sensitivity is improperly set or if a gas leak exists in the respiratory system which creates a negative change in proximal airway pressure. We report a case of ventilator autocycling in a paralyzed patient secondary to an endotracheal cuff leak which was misconstrued as assisted ventilation. We believe this is the first report of auto...

متن کامل

Bronchopulmonary Complications of Nasogastric tube Placement

Importance: Nasogastric tube (NGT) placement can cause severe thoracic and non-thoracic complications, which can cause severe morbidity and mortality. The knowledge of predisposing factors is crucial for prevention of these complications. Design: We report on three different cases of severe complication of NGT placement, which have not yet been described. Results: In the first case, intrathorac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016