OBJECTIVES To evaluate the success of certain methods that can be used in the removal of separated instruments from different levels in curved and straight canals. METHODS Instrument removal attempts were undertaken on 63 straight and 30 curved canals containing a pre-fractured instrument using the ultrasonics under the visualization of an operating microscope or conventional methods. In straight canals, a Masseran Kit was additionally used to these techniques. The success of instrument removal in relation to the techniques used and the location of the fragments in the root canal were evaluated. Successful treatment was defined by the removal or complete by passing of the fragments. RESULTS The overall success rate was found 93.3% with ultrasonics and 66.6% when only conventional methods were used in curved canals. In straight canals, also the success rate was the highest with ultrasonics (95.2%). This was followed by conventional method (80.9%) and the least by Masserann Kit (47.6%). When the success rate was investigated according to the location of the broken instruments, the lowest rate was found in the apical third of root canal. CONCLUSIONS Location of the fragment and the shape of the root canal influence the success of fractured instrument management. Ultrasonics under the visualization of an operating microscope was found to be an effective removal method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases.

The removal of fractured rotary nickel-titanium instruments from small, curved root canals is one of the most complex operative procedures in endodontics. There have been many different devices and techniques developed to remove fractured instruments, but none are consistently successful and all show a high incidence of canal damage such as perforation. A technique using a staging platform and ...

متن کامل

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

Research Paper: Comparison efficacy of calcium hydroxide removal by Revo-s, Protaper Rotary file from root canal

Abstract Introduction: The aim of this study was to evaluate the efficacy of two rotary instrument systems (ProTaper and Revo-s File) in removing calcium hydroxide residues from root canal walls Materials and Methods:Thirty human  maxillary incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl,and filled with a calcium hydroxide intracanal dr...

متن کامل

A method for retrieving endodontic or atypical nonendodontic separated instruments from the root canal: a report of two cases.

AIM This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. BACKGROUND The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. CASE REPORT This s...

متن کامل

Efficacy of Different Irrigation Systems Used to Remove Calcium Hydroxide from the Root Canal

Introduction: The present study aimed to compare the cleaning efficacy of passive ultrasonic irrigation (PUI), self-adjusting file (SAF), EndoVac, and conventional syringe irrigation (CSI) techniques on Ca(OH)2 removal from the root canal. Methods: This study was conducted on the mesial roots of 36 human mandibular molar teeth. After 1 month, the Ca(...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European Journal of Dentistry

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009