Closure of oroantral communications using biodegradable polyurethane foam: a long term study in rabbits.

نویسندگان

  • Susan H Visscher
  • Baucke van Minnen
  • M Barbara M van Leeuwen
  • Theo G van Kooten
  • Rudolf R M Bos
چکیده

An oroantral communication (OAC) is an open connection between the oral cavity and maxillary sinus. Closure of OACs is commonly performed with a surgical procedure using a mucoperiosteal flap. An alternative technique using synthetic biodegradable polyurethane (PU) foam for closure of OACs is presented. This PU foam is composed of hard urethane segments, and soft segments made of D/L lactide (50/50), epsilon-caprolactone, and 5% polyethyleneglycol (PEG). To evaluate the use of PU foam for this application, OACs were created in the edentulous part of the maxilla in 21 rabbits, after which PU foams were fitted in the defects. Results showed complete healing of the oral mucosa after 4-10 weeks, healing of the antral mucosal lining after 6 months and complete bony regeneration after 1 year. No reopening of the defects occurred and no maxillary sinusitis was observed. Degradation of the PU foam had not yet reached completion 1 year after implantation. In conclusion, PU foam with 5% PEG provides adequate closure of an OAC in the rabbit model to support healing of the oral and maxillary sinus mucosa. Longer time intervals are needed to assess the complete degradation of the PU foam.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closure of oroantral communications using biodegradable polyurethane foam: a feasibility study.

PURPOSE The aim of this study was to assess the feasibility of biodegradable polyurethane (PU) foam for closure of oroantral communications (OACs). PATIENTS AND METHODS Ten consecutive patients with OACs (existing <24 hours) were treated with PU foam. Standardized evaluations were performed at 2 weeks and 8 weeks after closure of the OAC. RESULTS In 5 patients, the OACs were closed successf...

متن کامل

Feasibility of conical biodegradable polyurethane foam for closure of oroantral communications.

PURPOSE To assess the feasibility of a conically shaped biodegradable polyurethane (PU) foam for closure of oroantral communications (OACs). PATIENTS AND METHODS In 10 consecutive patients, fresh OACs (present for <24 hours) were closed with PU foam. Standardized evaluations were performed at 2 and 8 weeks after closure of the OAC. Success was considered permanent closure of the OAC. RESULT...

متن کامل

Free Flap Donor Site Reconstruction: A Prospective Case Series Using an Optimized Polyurethane Biodegradable Temporizing Matrix

INTRODUCTION We recently published a 10-patient case series where free flap donor site reconstruction was performed as a 2-stage procedure using an integrating biodegradable polyurethane matrix (to form a neodermis), followed by definitive closure with an autologous split-skin graft. Two issues were revealed by this pilot study that led to further modification of the biodegradable temporizing m...

متن کامل

Long-term safety and efficacy of polyurethane foam-covered breast implants.

BACKGROUND Polyurethane foam-covered silicone gel-filled breast implants, introduced in the 1970s, were used in more than 110,000 American women. Because of concerns about possible toxicity, they were withdrawn from the US market in 1991. These implants remain popular in many parts of the world. OBJECTIVE The goal of this study was to evaluate long-term experience with polyurethane foam-cover...

متن کامل

Experimental and Numerical Simulation Investigation on Crushing Response of Foam-Filled Conical Tubes Stiffened with Annular Rings

In this paper, crashworthiness characteristics of conical steel tubes stiffened by annular rings and rigid polyurethane foam are investigated. For this purpose, wide circumferential rings are created from the outer surface of the conical tube at some determined areas along tube length. In fact, this method divides a long conical tube into several tubes of shorter length. When this structure is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 91 2  شماره 

صفحات  -

تاریخ انتشار 2009