Reduced chemical shift-induced phase errors at 3T using novel PC-MRI encoding gradients
نویسندگان
چکیده
Background Cardiovascular MRI benefits from improved SNR-efficiency at ≥3T [1,]2, but is subject to other sources of error, which require careful consideration when transitioning from primary use of 1.5T scanners. For example, chemical shift-induced PC-MRI errors [3] are increased at 3T compared to 1.5T. Chemical shift causes the complex perivascular fat signal to chemically shift into the vessel lumen and superposes with the complex blood (water) signal, thereby corrupting the phase (velocity) estimate. Chemical shift errors can be minimized by increasing the bandwidth (reduces the magnitude of the shifted fat signal), and by using an in-phase TE (TEIN, ensures fat and water are in-phase). Shorter TEs improve SNR, therefore it is advantageous that the minimum TEIN (TEIN,MIN) at 3T is 2.46ms, which is substantially shorter than TEIN,MIN=4.92ms at 1.5T, but such short TEs cannot be attained with conventional flowcompensated/flow-encoded (FCFE) velocity encoding strategies. The objective was to design a velocity encoding strategy void of conventional FCFE gradients that instead achieves through-plane velocity sensitivity using the slice select gradient, which yields a non-zero first gradient moment (M1) for the first PC-MRI TR: M1,1=X. The slice-select refocusing gradient (SSRG) lobe is time-shifted for the second TR to produce M1,2=X+Y, such that ΔM1=Y=π•g •VENC. We hypothesize that the proposed SSRG velocity encoding scheme, will permit the use of TEIN,MIN for chemical shift insensitive PC-MRI measures at 3T that are both faster and have improved SNR. Methods PC-MRI measurements were acquired in volunteers (N=10) on a Siemens 3T scanner with SSRG: TE/TR=2.46/ 4.46ms (TEIN,MIN), 192×132 matrix, 1.6mm ×6mm resolution, 30° flip angle, 814Hz/pixel (high bandwidth, HBW), 4 views-per-segment, 35.7ms temporal resolution, and VENC=200cm/s. 2D through-plane velocity encoding was acquired in the ascending aorta (aAo), main pulmonary artery (PA), and right and left pulmonary arteries (RPA and LPA). For comparison FCFE PC-MRI was acquired with the following changes: TE/TR=3.08/6.04ms (TEMID), 401Hz/px (low bandwidth, LBW), and 48.3ms temporal resolution. Eddy current background phase errors were corrected [4]. Intra-subject flow agreement (flow difference between vessels) was compared for SSRG and FCFE for all vessel pairs (aAo vs. PA, aAo vs. RPA+LPA, and PA vs. RPA+LPA).
منابع مشابه
Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRI
PURPOSE To evaluate convex gradient optimization (CVX) for increased spatiotemporal resolution and improved accuracy for phase-contrast MRI (PC-MRI). METHODS A conventional flow-compensated and flow-encoded (FCFE) PC-MRI sequence was compared with a CVX PC-MRI sequence using numerical simulations, flow phantom experiments, and in vivo experiments. Flow measurements within the ascending aorta,...
متن کاملImaging CSF Flow using Spin Echo Phase Contrast Velocity Encoded MRI at 3T
Introduction: Flow sensitive MRI techniques are typically based on gradient echo (GE) imaging. Such techniques are well validated, offer robust image quality, and are relatively insensitive to artefacts related to sources of field inhomogeneities. However, GE offers a relatively low SNR, particularly for imaging cerebrospinal fluid (CSF) which has a long T1 relaxation time and thus low signal a...
متن کاملRapid phase contrast MRI with minimum time gradient waveform design using convex optimization
Background Phase contrast MRI (PC-MRI) sequences conventionally use triangular and trapezoidal gradient waveforms to construct flow compensated and flow encoded (FCFE) [1] or Bipolar [2] velocity encoding gradients. This approach does not make optimal use of the available gradient hardware for all time points, but convex optimization (CVX) can be used to design minimum-duration, arbitrarily sha...
متن کاملQuantification and visualization of flow in small vessels of the Circle of Willis: time-resolved three-dimensional phase contrast MRI at 7T compared with 3T
Background A promising technique to measure blood flow is timeresolved three-dimensional phase contrast MRI (PCMRI). In small structures as the Circle of Willis (CoW), the resolution of the measurement needs to be high (< 1 mm). Image quality may be compromised when SNR decreases with increasing resolution which leads to blood flow direction uncertainty and flow quantification inaccuracies. To ...
متن کاملNoninvasive pressure measurement with 4D phase contrast MRI in patients with aortic coarctations
Background Aortic coarctation (CoA) is defined as a congenital narrowing of the descending thoracic aorta severe enough to create pressure gradient. In clinical routine, invasive catheter pressure measurements are considered the gold standard. Pressure gradients can also be estimated noninvasively from Doppler ultrasound (US) or 2D phase contrast (PC) MRI using a simplified Bernoulli equation [...