Three-dimensional time-of-flight secondary ion mass spectrometry imaging of a pharmaceutical in a coronary stent coating as a function of elution time.
نویسندگان
چکیده
Three-dimensional (3D) chemical images reveal the surface and subsurface distribution of pharmaceutical molecules in a coronary stent coating and are used to visualize the drug distribution as a function of elution time. The coronary stent coating consists of 25% (w/w) sirolimus in a poly(lactic-co-glycolic acid) (PLGA) matrix and is spray-coated onto metal coupons. Information regarding the 3D distribution of sirolimus in PLGA as a function of elution time was obtained by time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging using a Au(+) ion beam for analysis in conjunction with a C(60)(+) ion beam for sputter depth profiling. The examined formulation is shown to have large areas of the surface as well as subsurface channels that are composed primarily of the drug, followed by a drug-depleted region, and finally, a relatively homogeneous dispersion of the drug in the polymer matrix. Elution is shown to occur from the drug-enriched surface region on a relatively short time scale and more gradually from the subsurface regions of homogeneously dispersed drug. Bulk composition was also probed by X-ray photoelectron spectroscopy (XPS) depth profiling and confocal Raman imaging, the results of which substantiate the TOF-SIMS 3D images. Finally, the effectiveness of a C(60)(+) ion beam for use in 3D characterization of organic systems is demonstrated against another polyatomic ion source (e.g., SF(5)(+)).
منابع مشابه
Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملAnti-Asthma effect of an active components group from decoction of Pheretima Aspergillum and its chemical composition characterized by Liquid chromatography-quadrupole time of flight mass spectrometry
The decoction of Pheretima aspergillum is used as a traditional medicine for treatment of asthma in China with a long clinical history. The aim of the study was to investigate the anti-asthma activities of an active components group obtained from the decoction of Pheretima aspergillum in histamine and ovalubumin induced asthma guinea pigs. The incubation period of asthma, serum IFN-γ, IL-4 and ...
متن کاملAnti-Asthma effect of an active components group from decoction of Pheretima Aspergillum and its chemical composition characterized by Liquid chromatography-quadrupole time of flight mass spectrometry
The decoction of Pheretima aspergillum is used as a traditional medicine for treatment of asthma in China with a long clinical history. The aim of the study was to investigate the anti-asthma activities of an active components group obtained from the decoction of Pheretima aspergillum in histamine and ovalubumin induced asthma guinea pigs. The incubation period of asthma, serum IFN-γ, IL-4 and ...
متن کاملEfficient encoding and rapid decoding for interactive visualization of large three-dimensional hyperspectral chemical images.
Interactive visualization of data from a new generation of chemical imaging systems requires coding that is efficient and accessible. New technologies for secondary ion mass spectrometry (SIMS) generate large three-dimensional, hyperspectral datasets with high spatial and spectral resolution. Interactive visualization is important for chemical analysis, but the raw dataset size exceeds the memo...
متن کاملOptimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique
Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 81 24 شماره
صفحات -
تاریخ انتشار 2009