چکیده
Electric power system operators make critical decisions based on remote measurements. If those measurements are compromised, it is possible to make decisions that could lead to critical consequences. Of particular concern are unobservable attacks where compromised measurements are not flagged as erroneous by bad data detection algorithms. The use of secure measurement devices, such as PMUs, is one way to recognize such attacks. In this paper we present an algorithm based on integer programming for optimal placement of PMUs to detect unobservable electric power SCADA data integrity attacks. Alternatively, this algorithm can be used to identify minimal sets of existing PMUs whose data is needed to detect unobservable bad data attacks. We show that the algorithm is efficient on practical examples drawn from the power engineering literature.
منابع مشابه
Phasor Measurement Unit Selection for Unobservable Smart Grid Data Integrity Attack Detection
Electric power system operators make critical decisions based on remote measurements. If those measurements are compromised, it is possible to make decisions that could lead to critical consequences. Of particular concern are unobservable attacks in which compromised measurements are not flagged as erroneous by bad data detection algorithms. The use of secure measurement devices, such as PMUs, ...
متن کاملSmart grid data integrity attacks: characterizations and countermeasuresπ
Coordinated cyberattacks of power meter readings can be arranged to be undetectable by any bad data detection algorithm in the power system state estimation process. These unobservable attacks present a potentially serious threat to grid operations. Of particular interest are sparse attacks that involve the compromise of a modest number of meter readings. An efficient algorithm to find all unob...
متن کاملIdentification of "unobservable" cyber data attacks on power grids
This paper presents a new framework of identifying cyber data attacks on synchrophasor measurements. We focus on detecting “unobservable” cyber data attacks that cannot be detected by any existing detection method that purely relies on measurements received at one time instant. Leveraging the approximate low-rank property of phasor measurement unit (PMU) data, we formulate the unobservable cybe...
متن کاملCritical Measurement Set with PMU for Hybrid State Estimation
This paper presents a method for designing minimal measurement set that include both Supervisory Control And Data Acquisition (SCADA) and Synchronized Phasor Measurements Units (SPMU) data for a Hybrid State Estimation (HSE). The optimal location of Phasor Measurement Units (PMU) is performed by Binary Integer Linear Programming (BILP). Among these PMUs, the highest priority indexed PMUs are se...
متن کاملTime Stamp Attack in Smart Grid: Physical Mechanism and Damage Analysis
Many operations in power grids, such as fault detection and event location estimation, depend on precise timing information. In this paper, a novel time stamp attack (TSA) is proposed to attack the timing information in smart grid. Since many applications in smart grid utilize synchronous measurements and most of the measurement devices are equipped with global positioning system (GPS) for prec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IJCIP
دوره 7 شماره
صفحات -