The impact of IGRT for prostate radiotherapy on dosimetry and the traditional workflow practice of focus to skin distance measurements
نویسندگان
چکیده
Purpose: To assess the relevance of focus to skin distance (FSD) measurements for patients with intraprostatic gold seeds using an image guided radiation therapy (IGRT) protocol. The second aim of this study was to analyse the frequency and nature of isocentre shifts made during a course of treatment for patients with prostate cancer. Additionally, the impact of isocentre shifts on dosimetry, relative to the traditional method of basing dosimetric recalculations on FSD measurements was assessed. Methods and materials: Ten patients underwent prostate radiotherapy with intraprostatic gold seeds and an IGRT protocol. FSD measurements were taken on a daily basis pre-intervention and also post-intervention if an isocentre shift was made. Analysis of systematic and random isocentre shifts were made and compared to measured FSDs. An individual case study was carried out assessing the dosimetric impact of multiple isocentre shifts throughout a course of treatment and analysed against measured FSDs. Results: Ten patients received radiotherapy to the prostate (78 Gy/39 fractions). 390 treatment sessions were available for analysis, inclusive of 2340 measured FSDs. Measured FSDs were out of tolerance (greater than 1 cm difference from planned measurement) less than 2% of the total treatment sessions. Of the isocentre shifts made, 66% (160/242) were random and 34% (82/242) were systematic. The individual case study revealed 72% of treatment sessions required an isocentre shift with FSDs being outside tolerance for one session. Conclusions: FSD measurements in the era of intraprostatic gold seed IGRT have been reduced in importance. IGRT has improved the identification of systematic and random errors therefore allowing better visualisation of dosimetric impact these errors may cause. Our data suggest that FSD measurements for men undergoing IGRT for prostate cancer have minimal dosimetric impact.
منابع مشابه
Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields
Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...
متن کاملEffect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method
Background: Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions.Objective: The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiothe...
متن کاملSkin in vivo Dosimetry in Radiotherapy
Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...
متن کاملPhoton Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017
Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...
متن کاملA Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter
Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009