COOLL: Controlled On/Off Loads Library, a Public Dataset of High-Sampled Electrical Signals for Appliance Identification
نویسندگان
چکیده
This paper gives a brief description of the Controlled On/Off Loads Library (COOLL) dataset. This latter is a dataset of high-sampled electrical current and voltage measurements representing individual appliances consumption. The measurements were taken in June 2016 in the PRISME laboratory of the University of Orléans, France. The appliances are mainly controllable appliances (i.e. we can precisely control their turn-on/off time instants). 42 appliances of 12 types were measured at a 100 kHz sampling frequency.
منابع مشابه
An Efficient, Scalable Time-Frequency Method for Tracking Energy Usage of Domestic Appliances Using a Two-Step Classification Algorithm
Load monitoring is the practice of measuring electrical signals in a domestic environment in order to identify which electrical appliances are consuming power. One reason for developing a load monitoring system is to reduce power consumption by increasing consumers’ awareness of which appliances consume the most energy. Another example of an application of load monitoring is activity sensing in...
متن کاملBLOND, a building-level office environment dataset of typical electrical appliances
Energy metering has gained popularity as conventional meters are replaced by electronic smart meters that promise energy savings and higher comfort levels for occupants. Achieving these goals requires a deeper understanding of consumption patterns to reduce the energy footprint: load profile forecasting, power disaggregation, appliance identification, startup event detection, etc. Publicly avai...
متن کاملNeural Network Ensembles to Real-time Identification of Plug-level Appliance Measurements
Abstract— The problem of identifying end-use electrical appliances from their individual consumption profiles, known as the appliance identification problem, is a primary stage in both NonIntrusive Load Monitoring (NILM) and automated plug-wise metering. Therefore, appliance identification has received dedicated studies with various electric appliance signatures, classification models, and eval...
متن کاملVoltage Imbalance Compensation for Droop-Controlled Inverters in Islanded Microgrid
In this paper, a new control strategy is proposed for implementation in low-voltage microgrids with balanced/ unbalanced load circumstances. The proposed scheme contains, the power droop controllers, inner voltage and current loops, the virtual impedance loop, the voltage imbalance compensation. The proposed strategy balances the voltage of the single-phase critical loads by compensating the im...
متن کاملAn electrical load measurements dataset of United Kingdom households from a two-year longitudinal study
Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical lo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/1611.05803 شماره
صفحات -
تاریخ انتشار 2016