Movies of ice-embedded particles enhance resolution in electron cryo-microscopy.

نویسندگان

  • Melody G Campbell
  • Anchi Cheng
  • Axel F Brilot
  • Arne Moeller
  • Dmitry Lyumkis
  • David Veesler
  • Junhua Pan
  • Stephen C Harrison
  • Clinton S Potter
  • Bridget Carragher
  • Nikolaus Grigorieff
چکیده

Low-dose images obtained by electron cryo-microscopy (cryo-EM) are often affected by blurring caused by sample motion during electron beam exposure, degrading signal especially at high resolution. We show here that we can align frames of movies, recorded with a direct electron detector during beam exposure of rotavirus double-layered particles, thereby greatly reducing image blurring caused by beam-induced motion and sample stage instabilities. This procedure increases the efficiency of cryo-EM imaging and enhances the resolution obtained in three-dimensional reconstructions of the particle. Using movies in this way is generally applicable to all cryo-EM samples and should also improve the performance of midrange electron microscopes that may have limited mechanical stability and beam coherence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ESSAY Realizing thepotentialof electroncryo - microscopy

Structural analysis by electron microscopy of biological macromolecules or macromolecular assemblies embedded in rapidly frozen, vitreous ice has made great advances during the last few years. Electron cryo-microscopy, or cryo-EM, can now be used to analyse the structures of molecules arranged in the form of two-dimensional crystals, helical arrays or as single particles with or without symmetr...

متن کامل

Structural analysis of non-crystalline macromolecules: the ribosome.

Single-particle analysis using cryo-electron microscopy has emerged recently as a tool for elucidating the structure of biological macromolecules and their assemblies. A prerequisite for single-particle analysis is an ensemble of images of structurally identical particles in different orientations. There are a variety of techniques used for image processing of this type of object in electron mi...

متن کامل

Beam-induced motion correction for sub-megadalton cryo-EM particles

In electron cryo-microscopy (cryo-EM), the electron beam that is used for imaging also causes the sample to move. This motion blurs the images and limits the resolution attainable by single-particle analysis. In a previous Research article (Bai et al., 2013) we showed that correcting for this motion by processing movies from fast direct-electron detectors allowed structure determination to near...

متن کامل

Alignment of cryo-EM movies of individual particles by optimization of image translations.

Direct detector device (DDD) cameras have revolutionized single particle electron cryomicroscopy (cryo-EM). In addition to an improved camera detective quantum efficiency, acquisition of DDD movies allows for correction of movement of the specimen, due to both instabilities in the microscope specimen stage and electron beam-induced movement. Unlike specimen stage drift, beam-induced movement is...

متن کامل

High-resolution Single Particle Analysis from Electron Cryo-microscopy Images Using SPHIRE

SPHIRE (SPARX for High-Resolution Electron Microscopy) is a novel open-source, user-friendly software suite for the semi-automated processing of single particle electron cryo-microscopy (cryo-EM) data. The protocol presented here describes in detail how to obtain a near-atomic resolution structure starting from cryo-EM micrograph movies by guiding users through all steps of the single particle ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Structure

دوره 20 11  شماره 

صفحات  -

تاریخ انتشار 2012