Withdrawal of mechanical ventilation in anticipation of death in the intensive care unit.
نویسندگان
چکیده
BACKGROUND In critically ill patients who are receiving mechanical ventilation, the factors associated with physicians' decisions to withdraw ventilation in anticipation of death are unclear. The objective of this study was to examine the clinical determinants that were associated with the withdrawal of mechanical ventilation. METHODS We studied adults who were receiving mechanical ventilation in 15 intensive care units, recording base-line physiological characteristics, daily Multiple Organ Dysfunction Scores, the patient's decision-making ability, the type of life support administered, the use of do-not-resuscitate orders, the physician's prediction of the patient's status, and the physician's perceptions of the patient's preferences about the use of life support. We examined the relation between these factors and withdrawal of mechanical ventilation, using Cox proportional-hazards regression analysis. RESULTS Of 851 patients who were receiving mechanical ventilation, 539 (63.3 percent) were successfully weaned, 146 (17.2 percent) died while receiving mechanical ventilation, and 166 (19.5 percent) had mechanical ventilation withdrawn. The need for inotropes or vasopressors was associated with withdrawal of the ventilator (hazard ratio, 1.78; 95 percent confidence interval, 1.20 to 2.66; P=0.004), as were the physician's prediction that the patient's likelihood of survival in the intensive care unit was less than 10 percent (hazard ratio, 3.49; 95 percent confidence interval, 1.39 to 8.79; P=0.002), the physician's prediction that future cognitive function would be severely impaired (hazard ratio, 2.51; 95 percent confidence interval, 1.28 to 4.94; P=0.04), and the physician's perception that the patient did not want life support used (hazard ratio, 4.19; 95 percent confidence interval, 2.57 to 6.81; P<0.001). CONCLUSIONS Rather than age or the severity of the illness and organ dysfunction, the strongest determinants of the withdrawal of ventilation in critically ill patients were the physician's perception that the patient preferred not to use life support, the physician's predictions of a low likelihood of survival in the intensive care unit and a high likelihood of poor cognitive function, and the use of inotropes or vasopressors.
منابع مشابه
بررسی عوارض ریوی ناشی از تهویه مکانیکی در نوزادان بستری در بخش NICU
Introduction & Objective: The main indication of mechanical ventilation is in the treatment of neonates with respiratory failure. With the increased use of mechanical ventilation, its complications have increased too. The aim of this study was to evaluate the prevalence of complications and short-term improvement in infants undergoing mechanical ventilation in the neonatal intensive care unit (...
متن کاملEvaluating the Short-Term Outcome of Mechanically Ventilated Neonates Admitted to the Neonatal Intensive Care Unit of Besat Hospital, Hamadan, Iran
Background Many neonates admitted to Neonatal Intensive Care Unit (NICU) need mechanical ventilation for recovery. This study was designed to evaluate the short-term outcome of mechanically ventilated neonates admitted to NICU. <span style="fon...
متن کاملExposure keratitis in mechanical ventilatory patients admitted to intensive care unit
Background & Aims: Exposure Keratitis (EK) is a common problem in critically ill patients admitted to the Intensive Care Unit (ICU). We conducted exposure keratitis in mechanical ventilatory patients in the intensive care unit of Imam Khomeini Hospital in Urmia for five years. Materials & Methods: In this retrospective cross-sectional study, the records of the patients were taken from the medi...
متن کاملCauses and Outcomes of Respiratory Distress in Neonates Hospitalized in the Neonatal Intensive Care Unit of Be’sat Hospital in Hamadan, Iran
Background Neonatal respiratory distress is one the most common problems in the first few day of neonatal life. The present study intended to determine the frequency of the causes and outcomes of respiratory distress in neonates hospitalized in the neonatal intensive care unit (NICU) in Hamadan city, Iran. Materials and Methods In this descriptive and cross-sectional study, all the neonates wi...
متن کاملProviding palliative care for patients receiving mechanical ventilation in an intensive care unit Part 2: Withdrawing ventilation
Mechanical ventilation is often withdrawn from patients in expectation of death in intensive care units (ICUs). This process involves close collaboration between families and loved ones, physicians, nurses, respiratory therapists, and other healthcare providers. Because withdrawal of ventilation has important symbolic meaning to families and healthcare providers alike, it is a critical aspect o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The New England journal of medicine
دوره 349 12 شماره
صفحات -
تاریخ انتشار 2003