Fusion of Magnetometer and Gradiometer Sensors of MEG in a Beamforming Framework
نویسندگان
چکیده
Novel neuroimaging techniques have provided unprecedented information on the structure and function of the living human brain. Multimodal fusion of data from different sensors promises to radically improve this understanding, yet optimal methods have not yet been developed. Here, we demonstrate a novel method for combining multichannel signals. We show how this method can be used to fuse signals from the magnetometer and gradiometer sensors used in magnetoencephalography (MEG) and, through extensive experiments using simulation, head phantom and real MEG data, show that it is both robust and accurate. This new approach works by assuming that the lead-fields have multiplicative error. The criterion to estimate the error is given within the beamforming framework such that the estimated power is minimised in the worst case scenario. The method is compared to, and found better than, existing approaches. The closed-form solution and the conditions under which the multiplicative error can be optimally estimated are provided. This novel approach can also be employed for multimodal fusion of other multichannel signals such as MEG and EEG.
منابع مشابه
Choice of Magnetometers and Gradiometers after Signal Space Separation
BACKGROUND Modern Elekta Neuromag MEG devices include 102 sensor triplets containing one magnetometer and two planar gradiometers. The first processing step is often a signal space separation (SSS), which provides a powerful noise reduction. A question commonly raised by researchers and reviewers relates to which data should be employed in analyses: (1) magnetometers only, (2) gradiometers only...
متن کاملDouble Relaxation Oscillation SQUID Systems for Biomagnetic Multichannel Measurements
Multichannel superconducting quantum interference device (SQUID) systems based on double relaxation oscillation SQUIDs (DROS) were developed for measuring magnetocardiography (MCG) and magnetoencephalography (MEG) signals. Since DROS provides large fluxto-voltage transfer coefficients, about 10 times larger than the DC SQUIDs, direct readout of the SQUID output was possible using compact roomte...
متن کاملThe effect of environmental noise on magnetometer- and gradiometer-based MEG systems
The ability of an MEG system to resolve small or deep sources is solely determined by the achieved signal-to-noise ratio (SNR). Ideal MEG sensors should exhibit a large gain relative to the brain signals and should also effectively attenuate the environmental and brain noise. Designing the system for large signal strength without regard for noise attenuation, or designing for excellent noise at...
متن کاملCortical Lead Fields of Electroencephalographic and Magnetoencephalographic Sensors
The spatial relationship of electroencephalography (EEG) and magnetoencephalography (MEG) to brain activation is quantified as their cortical lead fields: the sensitivity of each sensor to activation of each cortical location. Here we map the lead fields of EEG and MEG across the cortical surface using a realistic boundary element model with four compartments. These calculations demonstrate tha...
متن کاملRoutes for GMR-Sensor Design in Non-Destructive Testing
GMR sensors are widely used in many industrial segments such as information technology, automotive, automation and production, and safety applications. Each area requires an adaption of the sensor arrangement in terms of size adaption and alignment with respect to the field source involved. This paper deals with an analysis of geometric sensor parameters and the arrangement of GMR sensors provi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011