Differential pulse cathodic voltammetric determination of floctafenine and metopimazine.

نویسندگان

  • Azza A Gazy
  • Ekram M Hassan
  • Mohamed H Abdel-Hay
  • Tarek S Belal
چکیده

A simple, rapid and sensitive voltammetric method for the determination of floctafenine (FFN) and metopimazine (MPZ) was developed. Well-defined cathodic waves were obtained for both drugs in Britton-Robinson buffer pH 9.0 using the differential-pulse mode at the hanging mercury drop electrode (HMDE). The current-concentration relationship was found to be linear over the ranges 0.4-3.6 and 0.4-2.4 microg ml(-1) for FFN and MPZ, respectively. The quantification of the two drugs in their pharmaceutical formulations was carried out using the proposed voltammetric method and compared with spectrophotometric analysis data. The mechanisms of the electrode reactions for the two drugs were proposed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid

In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...

متن کامل

Determination of trace amounts of lead by adsorptive cathodic stripping voltammetry in the presence of xylenol orange

Lead forms the complexes with xylenol orange in the basic solution. An adsorptivedifferential pulse stripping method for the determination of lead is proposed. The procedureinvolves an adsorptive accumulation of lead on a hanging mercury drop electrode (HMDE) inthe presence of xylenol orange, followed by reduction of adsorbed lead by voltammetric scanusing differential pulse modulation. The opt...

متن کامل

Differential Pulse Voltammetric Determination of Free Chlorine for Water Disinfection Process

The electrochemical detection of free chlorine based on the reduction at a gold electrode has been studied. The differential pulse voltammetric curves exhibited well-defined cathodic peaks. Investigations with this system suggested that the active species in the cathodic reaction is HClO. Excellent reproducibility was demonstrated at pH 5. The peak height could be used for accurate and rapid de...

متن کامل

Differential pulse and square-wave cathodic stripping voltammetry of xanthine and xanthosine at a mercury electrode.

The surface activity of xanthine (Xan) and xanthosine (Xano) at a hanging mercury drop electrode (HMDE) was studied using out-of-phase ac and cyclic dc voltammetry. The results show that Xan and Xano were strongly adsorbed and chemically interacted with the charged mercury surface, which is the prerequisite step for applying the cathodic adsorptive stripping voltammetric determination of such b...

متن کامل

Cathodic adsorptive stripping voltammetric determination of prednisolone in pharmaceutical preparation and human urine.

Differential pulse cathodic adsorptive stripping voltammetric method was developed for the determination of prednisolone based on electrochemical reduction of the drug at a hanging mercury drop electrode (HMDE) in 0.04 M Britton-Robinson buffer pH 3.5. The peak current varied linearly over the concentration range 7.21-144.2 ng/ml prednisolone with limit of detection and limit of quantification ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 43 4  شماره 

صفحات  -

تاریخ انتشار 2007