Spectrophotometric measurement of carboxyhemoglobin and methemoglobin in blood.

نویسندگان

  • F L Rodkey
  • T A Hill
  • L L Pitts
  • R F Robertson
چکیده

This paper describes separate spectrophotometric procedures for rapidly measuring carboxyhemoglobin (COHb) and methemoglobin (MetHb) in blood. Absorbance measurements are made in the Soret region at a blood dilution near 1000-fold. For COHb estimation, the diluent contains sodium hydrosulfite, providing the two-component system COHb--Hb for absorbance measurements at 420 and 432 nm. The NA2S2O4 effectively prevents dissociation of COHb by oxygen. For MetHb estimation, the diluent contains KCN and carbon monoxide, providing the two-component system COHb--CNMetHb. Absorbance measurements are made at 420 nm, before and after addiely analyzed for the total of all MetHb forms present. Each procedure requires about 3 muL of blood and can be applied to human or animal blood. Results obtained by the present methods are in satisfactory agreement with currently accepted procedures, which require much larger samples or more elaborate equipment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The spectrophotometric measurement of carboxyhemoglobin.

A simple, reliable and rapid method for the spectrophotometric determina­ tion of carboxyhemoglobin in fresh blood is described. A blood hemolysate is prepared by diluting a blood sample with 0.4 percent NH4 OH. Addition of sodium dithionite deoxygenates hemoglobin (and reduces methemoglobin if present) without affecting carboxyhemoglobin. Comparison of the 541/555 nm absorbance ratio for the h...

متن کامل

Performanceof an Automated Six-Wavelength Measurement of HemoglobinDerivatives

A new instrument for spectrophotometric determination of oxygen saturation (S) and the fractions of carboxyhemoglobin (FHo) and methemoglobin (FHI), the Hemoximeter OSM3 (Radiometer), was tested by comparativemeasurements with a multiwavelength method. We found that it gave reliable results for freshly drawn samples from patients. When samples with artificially induced high proportions of HbCO ...

متن کامل

Methemoglobin in blood as determined by double-wavelength spectrophotometry.

We describe spectrophotometric determination of methemoglobin (Met-Hb) in blood by absorbance differences at two wavelengths (characteristic of the instrument used) in the 500-600 nm region. Blood is diluted 100- to 200-fold with a solution containing KCN and carbon monoxide to convert hemoglobin to carboxyhemoglobin and Met-Hb to cyanomethemoglobin (CN-Met-Hb). Carboxyhemoglobin has the same a...

متن کامل

Rapid multicomponent analysis of hemoglobin derivatives for controlled antidotal use of methemoglobin-forming agents in cyanide poisoning.

When cyanide poisoning is treated with a methemoglobin-forming agent, oxidative metabolism is protected at the expense of the oxygen capacity of the blood. The affinity of methemoglobin for CN- is high enough to compete with cytochrome oxidase, which protects the latter from becoming blocked, but all hemoglobin used for this purpose is lost for the transport of oxygen. Therefore, the fractions ...

متن کامل

Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 8  شماره 

صفحات  -

تاریخ انتشار 1979