Stress distribution on dentin-cement-post interface varying root canal and glass fiber post diameters. A three-dimensional finite element analysis based on micro-CT data

نویسندگان

  • Priscilla Cardoso LAZARI
  • Rodrigo Caldeira Nunes de OLIVEIRA
  • Rodolfo Bruniera ANCHIETA
  • Erika Oliveira de ALMEIDA
  • Amilcar Chagas FREITAS JUNIOR
  • Sidney KINA
  • Eduardo Passos ROCHA
چکیده

OBJECTIVE The aim of the present study was to analyze the influence of root canal and glass fiber post diameters on the biomechanical behavior of the dentin/cement/post interface of a root-filled tooth using 3D finite element analysis. MATERIAL AND METHODS Six models were built using micro-CT imaging data and SolidWorks 2007 software, varying the root canal (C) and the glass fiber post (P) diameters: C1P1-C=1 mm and P=1 mm; C2P1-C=2 mm and P=1 mm; C2P2-C=2 mm and P=2 mm; C3P1-C=3 mm and P=1 mm; C3P2-C=3 mm and P=2 mm; and C3P3-C=3 mm and P=3 mm. The numerical analysis was conducted with ANSYS Workbench 10.0. An oblique force (180 N at 45º) was applied to the palatal surface of the central incisor. The periodontal ligament surface was constrained on the three axes (x=y=z=0). Maximum principal stress (σ(max)) values were evaluated for the root dentin, cement layer, and glass fiber post. RESULTS The most evident stress was observed in the glass fiber post at C3P1 (323 MPa), and the maximum stress in the cement layer occurred at C1P1 (43.2 MPa). The stress on the root dentin was almost constant in all models with a peak in tension at C2P1 (64.5 MPa). CONCLUSION The greatest discrepancy between root canal and post diameters is favorable for stress concentration at the post surface. The dentin remaining after the various root canal preparations did not increase the stress levels on the root.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of different materials used for post construction and stress distribution in the radicular dentin using finite element method

Evaluation of different materials used for post construction and stress distribution in the radicular dentin using finite element method Dr. S. Nokar *- Dr. AS. Mostafavi ** *Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Tehran University / Medical Sciences. **Resident of Prosthodontics Dept., Faculty of Dentistry, Tehran University / Medical Sciences. Abstract Background a...

متن کامل

Effect of Resin Cement Porosity on Retention of Glass-Fiber Posts to Root Dentin: An Experimental and Finite Element Analysis.

The aim of this study was to evaluate the effect of porosity of self-adhesive resin on the stress distribution, post retention and failure mode of fiber post cemented to human root dentin. Ten human central upper incisors with circular root canal were selected. They were sectioned with 15 mm and were endodontically filled. The roots were scanned using micro-CT after post space preparation for r...

متن کامل

Stress distribution of oval and circular fiber posts in amandibular premolar: a three-dimensional finite element analysis

PURPOSE The aim of the present study was to evaluate the effects of posts with different morphologies on stress distribution in an endodontically treated mandibular premolar by using finite element models (FEMs). MATERIALS AND METHODS A mandibular premolar was modeled using the ANSYS software program. Two models were created to represent circular and oval fiber posts in this tooth model. An o...

متن کامل

Effect of Intracanal Dentin Conditioning with Xylene, Phosphoric Acid and Chlorhexidine on Bond Strength to Glass Fiber Post with Self-Adhesive Cement

Background and Aim: Debonding is the most commonly encountered failure in teeth restored with fiber posts that mainly occurs at the weakest interface (dentin-cement interface). Thus, reinforcement of this interface is mandatory. The aim of this study was to evaluate the effect of different root dentin surface treatments after post space preparation on bond strength of fiber posts cemented with ...

متن کامل

Stress Distribution in Roots Restored with Fiber Posts and An Experimental Dentin Post: 3D-FEA.

The aim of this study was to compare the stress distribution in radicular dentin of a maxillary canine restored with either a glass fiber post, carbon fiber post or an experimental dentin post using finite element analysis (3D-FEA). Three 3D virtual models of a maxillary canine restored with a metal-ceramic crown and glass fiber post (GFP), carbon fiber post (CFP), and experimental dentin post ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2013