Extra- and Intracochlear Electrocochleography in Cochlear Implant Recipients.

نویسندگان

  • Adrian Dalbert
  • Flurin Pfiffner
  • Christof Röösli
  • Konrad Thoele
  • Jae Hoon Sim
  • Rahel Gerig
  • Alexander M Huber
چکیده

OBJECTIVE To monitor cochlear function by extra- and intra-cochlear electrocochleography (ECoG) during and after cochlear implantation and thereby to enhance the understanding of changes in cochlear function following cochlear implantation surgery. METHODS ECoG responses to acoustic stimuli of 250, 500 and 1,000 Hz were recorded in 9 cochlear implant recipients with presurgical residual hearing. During surgery extracochlear ECoG recordings were performed before and after insertion of the cochlear implant electrode array. After insertion of the electrode array, intracochlear ECoG recordings were conducted using intracochlear electrode contacts as recording electrodes. Intracochlear ECoG recordings were performed up to 6 months after implantation.ECoG findings were correlated with findings from audiometric tests. RESULTS Extra- and intracochlear ECoG responses could be recorded in all subjects. Extracochlear ECoG recordings during surgery showed moderate changes.Loss or reduction of the ECoG signal at all three frequencies did not occur during cochlear implantation. During the first week following surgery, conductive hearing loss, due to middle ear effusion, led to a decrease in intracochlear ECoG signal amplitudes. This was not attributable to changes of cochlear function. All persistent reductions in ECoG response magnitude after normalization of the tympanogram occurred during the first week following implantation. Thresholds of ECoG signals were at or below hearing thresholds in all cases. CONCLUSION Gross intracochlear trauma during surgery appears to be rare. In the early postoperative phase the ability to assess cochlear status by ECoG recordings was limited due to the regular occurrence of middle ear effusion.Still, intracochlear ECoG along with tympanogram recordings suggests that any changes of low-frequency cochlear function occur mainly during the first week after cochlear implantation. ECoG seems to be a promising tool to objectively assess changes in cochlear function in cochlear implant recipients and may allow further insight into the mechanisms underlying the loss of residual hearing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography

Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological chan...

متن کامل

Ups and Downs in 75 Years of Electrocochleography

Before 1964, electrocochleography (ECochG) was a surgical procedure carried out in the operating theatre. Currently, the newest application is also an intra-operative one, often carried out in conjunction with cochlear implant surgery. Starting in 1967, the recording methods became either minimal- or not-invasive, i.e., trans-tympanic (TT) or extra tympanic (ET), and included extensive studies ...

متن کامل

Evaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window

HYPOTHESIS This study aimed to evaluate whether there is a difference in the degree of intracochlear trauma when the cochlear implant electrode arrays is inserted through different quadrants of the round window membrane. BACKGROUND The benefits of residual hearing preservation in cochlear implant recipients have promoted the development of atraumatic surgeries. Minimal trauma during electrode...

متن کامل

Characterizing Electrocochleography in Cochlear Implant Recipients with Residual Low-Frequency Hearing

Objective: Lay the groundwork for using electrocochleography (ECochG) as a measure of cochlear health, by characterizing typical patterns of the ECochG response observed across the electrode array in cochlear implant recipients with residual hearing. Methods: ECochG was measured immediately after electrode insertion in 45 cochlear implant recipients with residual hearing. The Cochlear Response ...

متن کامل

Intracochlear Recordings of Acoustically and Electrically Evoked Potentials in Nucleus Hybrid L24 Cochlear Implant Users and Their Relationship to Speech Perception

The Hybrid cochlear implant (CI) has been developed for individuals with high frequency hearing loss who retain good low frequency hearing. Outcomes have been encouraging but individual variability is high; the health of the cochlea and the auditory nerve may be important factors driving outcomes. Electrically evoked compound action potentials (ECAPs) reflect the response of the auditory nerve ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Audiology & neuro-otology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2015