Lead in bone: sampling and quantitation using K X-rays excited by 109Cd.
نویسندگان
چکیده
Lead in bone can be measured in vivo using gamma-rays from a 109Cd source to excite lead K X-rays. Normalization of lead X-ray amplitudes to that of the elastically backscattered 88 keV gamma-rays produces a determination of the concentration of lead in bone mineral that is accurate and insensitive to variations in measurement or bone geometry. For in vivo tibia measurements, a typical precision (1 SD) of +/- 5 micrograms lead (g bone mineral)-1 is achieved for an effective dose equivalent of 2.1 microSv. Measurement can be made of any superficial bone site, but precision will vary approximately as the inverse of the square root of the mass of bone mineral sampled. The apparatus required for this technique is readily transportable, and mobile laboratory facilities are easily established.
منابع مشابه
In vivo X-ray fluorescence of lead in bone: review and current issues.
Bone lead measurements can assess long-term lead dosimetry because the residence time of lead in bone is long. Bone lead measurements thus complement blood and plasma lead measurements, which reflect more short-term exposure. Although the noninvasive, in vivo measurement of lead in bone by X-ray fluorescence (XRF) has been under development since the 1970s, its use is still largely confined to ...
متن کاملTibia lead levels and methodological uncertainty in 12-year-old children.
In vivo bone lead measurements with 109Cd-based K-shell X-ray fluorescence (XRF) have been used to assess long-term lead exposure in adults. Tibia lead levels were measured in 210 children (106 boys, 104 girls) of 11-12(1/2) years of age in a lead smelter town and in a control (nonexposed) town. Tibia lead levels, methodological uncertainties, and models of some of the factors influencing them ...
متن کاملCalculating the uncertainty in lead concentration for in vivo bone lead x-ray fluorescence.
A revised mathematical treatment of the calibration line intercept has been published for in vivo bone lead measurements using 109Cd-based K-shell x-ray fluorescence. The revised calibration line treatment prompts changes, presented herein, to the method for calculating the measurement uncertainty.
متن کاملA COMPARISON BETWEEN THERMAL AND X RADIOGRAPHY FOR STUDYING THE INTERNAL STRUCTURE OF BIOLOGICAL
ABSTRACT Background: With respect to the difference in the interaction of thermal neutron and X rays with matter, using two radiography systems of thermal neutron and X rays will yield highly valuable information for studying the inner structure of biologic samples. Methods: The high sensitivity of thermal neutron to hydrogen, in particular, has led to recognizing this system as a useful tool ...
متن کاملEvaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff
Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...