BACKGROUND Myocardial extravascular extracellular volume fraction (Ve) measures quantify diffuse fibrosis not readily detectable by conventional late gadolinium (Gd) enhancement (LGE). Ve measurement requires steady state equilibrium between plasma and interstitial Gd contrast. While a constant infusion produces steady state, it is unclear whether a simple bolus can do the same. Given the relatively slow clearance of Gd, we hypothesized that a bolus technique accurately measures Ve, thus facilitating integration of myocardial fibrosis quantification into cardiovascular magnetic resonance (CMR) workflow routines. Assuming equivalence between techniques, we further hypothesized that Ve measures would be reproducible across scans. METHODS In 10 volunteers (ages 20-81, median 33 yr, 3 females), we compared serial Ve measures from a single short axis slice from two scans: first, during a constant infusion, and second, 12-50 min after a bolus (0.2 mmol/kg gadoteridol) on another day. Steady state during infusion was defined when serial blood and myocardial T1 data varied <5%. We measured T1 on a 1.5 T Siemens scanner using a single-shot modified Look Locker inversion recovery sequence (MOLLI) with balanced SSFP. To shorten breath hold times, T1 values were measured with a shorter sampling scheme that was validated with spin echo relaxometry (TR = 15 sec) in CuSO4-Agar phantoms. Serial infusion vs. bolus Ve measures (n = 205) from the 10 subjects were compared with generalized estimating equations (GEE) with exchangeable correlation matrices. LGE images were also acquired 12-30 minutes after the bolus. RESULTS No subject exhibited LGE near the short axis slices where Ve was measured. The Ve range was 19.3-29.2% and 18.4-29.1% by constant infusion and bolus, respectively. In GEE models, serial Ve measures by constant infusion and bolus did not differ significantly (difference = 0.1%, p = 0.38). For both techniques, Ve was strongly related to age (p < 0.01 for both) in GEE models, even after adjusting for heart rate. Both techniques identically sorted older individuals with higher mean Ve values. CONCLUSION Myocardial Ve can be measured reliably and accurately 12-50 minutes after a simple bolus. Ve measures are also reproducible across CMR scans. Ve estimation can be integrated into CMR workflow easily, which may simplify research applications involving the quantification of myocardial fibrosis.
منابع مشابه
Cardiac T1 mapping in congenital heart disease: bolus versus infusion protocol for measurement of myocardial extracellular volume
Background Measurement of myocardial extracellular volume fraction (ECV) with T1 mapping cardiac magnetic resonance (CMR) before and after the application of a gadolinium-based extracellular contrast agent enables the assessment of diffuse myocardial fibrosis. The equilibrium between blood and myocardium contrast concentration required for ECV measurements can be achieved with a primed contrast...
متن کاملExtracellular volume fraction measured by MOLLI: slow infusion versus bolus
Background Myocardial extracellular volume fraction (Ve) measures from myocardial and blood pool T1 data quantify diffuse fibrosis (Flett, 2010) not detectable by conventional late gadolinium (Gd) enhancement, but require steady state equilibrium between plasma and interstitium. While a bolus with a lengthy infusion produces steady state for Ve measures, it is unclear whether a Gd contrast bolu...
متن کاملSuccessful surgical repair of a giant coronary-pulmonary artery fistula: role of magnetic resonance imaging.
15. Mcgraw K, Wong S. Forming inferences about some intraclass correlation coefficients. Psychol Methods 1996;1:30–46. 16. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307–10. 17. SPSS for Windows, Rel. 17.0.0. SPSS Inc., Chicago, USA; 2008. 18. Walther T, Schubert A, Falk V, Binner C, Kanev A, Bleiziffer S et al. Re...
متن کاملT1 mapping for myocardial extracellular volume measurement by CMR: bolus only versus primed infusion technique.
OBJECTIVES The aim of this study was to determine the accuracy of the contrast "bolus only" T1 mapping cardiac magnetic resonance (CMR) technique for measuring myocardial extracellular volume fraction (ECV). BACKGROUND Myocardial ECV can be measured with T1 mapping before and after contrast agent if the contrast agent distribution between blood/myocardium is at equilibrium. Equilibrium distri...
متن کاملA long way from the heart.
the gadolinium-enhanced myocardium: adjustment for factors affecting interpatient comparison. Magn Reson Med 2011;65:1407–15. 21. Schneider CA,Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 yearsof image analysis. Nat Methods 2012;9:671–5. 22. Flett AS, Hayward MP, Ashworth MT, Hansen MS, Taylor AM, Elliott PM et al. Equilibrium contrast cardiovascular magnetic resonance for the measurement o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -