Dry electrolyte-balanced heparinized syringes evaluated for determining ionized calcium and other electrolytes in whole blood.
نویسندگان
چکیده
By analyzing whole blood containing no anticoagulants (uncoagulated whole blood) immediately after collection, we evaluated the relative changes in the concentrations of ionized calcium and other electrolytes in whole blood collected in dry heparinized syringes and in serum prepared from blood collected in evacuated blood-collection tubes. Using these dry heparinized syringes, we collected and analyzed whole blood that contained either 33 or 13 int. units of lithium heparin or 40 int. units of electrolyte-balanced heparin per milliliter of blood. We evaluated the effects both of these heparins at different concentrations of ionized calcium and of the incomplete filling of the syringes. We conclude that: (a) when analyzed within 2-3 min after collection, uncoagulated whole blood provides ionized calcium results unaffected by anticoagulants or cellular metabolism; (b) the preparation of serum unpredictably changes ionized calcium; (c) the use of dry electrolyte-balanced heparin virtually eliminates the interference in ionized calcium concentrations between 0.9 and 1.6 mmol/L; and (d) incomplete filling of electrolyte-balanced heparinized syringes produces no effect in syringes two-thirds full (60 int. units/mL heparin concentration) and a small effect in syringes one-third full (120 int. units/mL heparin).
منابع مشابه
Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients.
We have compared ionized magnesium assays in the Nova 8 electrolyte analyser using dry balanced heparinized syringes and self-prepared heparinized syringes. Thirty blood specimens were obtained into syringes either operator-prepared with liquid sodium heparin or commercially manufactured dry balanced heparinized syringes. There was a good correlation between results from the two syringes. The m...
متن کاملElectrolyte-balanced heparin in blood gas syringes can introduce a significant bias in the measurement of positively charged electrolytes.
BACKGROUND Heparin binds positively charged electrolytes. In blood gas syringes, electrolyte-balanced heparin is used to prevent a negative bias in electrolyte concentrations. The potential pre-analytical errors introduced by blood gas syringes are largely unknown. Here, we evaluate electrolyte concentrations in non-anticoagulated blood compared with concentrations measured in electrolyte-balan...
متن کاملLiquid Heparin Anticoagulant Produces More Negative Bias in the Determination of Ionized Magnesium than Ionized Calcium
The ionized calcium level in blood is known to be falsely decreased when self-prepared liquid heparin anticoagulant is used, due to dilution and binding effects. The effect of liquid heparin on the determination of ionized magnesium is not as well understood. We compared the effect of liquid sodium heparin on the determination of ionized calcium and magnesium in 44 clinical samples using two ty...
متن کاملInterference in ionized calcium measurements by heparin salts.
We determined the suitability of various heparin salts used for anticoagulation of whole-blood specimens for measurement of ionized calcium (iCa), blood gases, and electrolytes. We were particularly interested in a new heparin product containing both zinc and lithium cations (CNLZ heparin), in which the binding sites with greatest affinity for divalent cations are bound with zinc and low-affini...
متن کاملD-phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK): alternative anticoagulant to heparin salts for blood gas and electrolyte specimens.
D-Phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK), a selective thrombin inhibitor, was evaluated as an alternative anticoagulant to lithium heparin (LiHep) for blood gas and whole-blood electrolyte analyses. Initial studies in serum revealed a negative proportional bias for ionized calcium (iCa) concentration measured in the range of increasing concentrations of LiHep (-0.02 mmol/L...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 37 10 Pt 1 شماره
صفحات -
تاریخ انتشار 1991