Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty
نویسندگان
چکیده
Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.
منابع مشابه
Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation
BACKGROUND AND PURPOSE Revision total hip arthroplasty (THA) due to recurrent dislocations is associated with a high risk of persistent instability. We hypothesized that the use of dual-mobility cups would reduce the risk of re-revision due to dislocation after revision THA. PATIENTS AND METHODS 228 THA cup revisions (in 228 patients) performed due to recurrent dislocations and employing a sp...
متن کاملEarly Intraprosthetic Dislocation of A Dual Mobility Acetabular Construct
Dislocations represent one of the more common postoperative complications seen after total hip arthroplasty (THA) with estimates ranging from 0.2 to 7% in primary cases and as high as 25% in revision surgeries [1]. In the early 1970s, Giles Bousquet developed a dual mobility (DM) acetabular cup with the goal of reducing dislocation rates. The dual mobility (DM) design consists of two articulati...
متن کاملNo dislocations after primary hip arthroplasty with the dual mobility cup in displaced femoral neck fracture in patients with dementia. A one-year follow-up in 20 patients
PURPOSE The aim of this study was to describe the dislocation rates, reoperation rates and mortality 30 day and one year following THA with AVANTAGE® dual mobility cup among dementia patients with an acute displaced intracapsular femoral neck fracture. PATIENTS AND METHODS From 2010 to 2014 we identified 20 hip fracture patients with dementia, who have had total hip arthroplasty with the AVAN...
متن کاملEarly results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head
INTRODUCTION Osteonecrosis of the femoral head (ONFH) remains a therapeutic challenge for patients undergoing total hip arthroplasty (THA). The majority of these patients are young with high functional demand, and show an increased risk of dislocation following surgery than patients with osteoarthritis. The use of double mobility cup (DMC) has been linked with lower rates of complications when ...
متن کاملDissociation of Polyethylene Liner of the Dual Mobility Acetabular Component after Closed Reduction of Dislocation: A Case Report
A dual mobility acetabular component has a structure that combines a polyethylene liner and a femoral head, unlike the general design of acetabular cups, making the dissociation of a polyethylene liner highly unlikely. In addition, it increases the range of motion and reduces the possibility of dislocations by increasing a jump distance. A fifty-one-year-old male who had received total hip arth...