Serial measurement of integrated ultrasonic backscatter in human cardiac allografts for the recognition of acute rejection.
نویسندگان
چکیده
Cyclic variation of integrated ultrasonic backscatter (IB) was noninvasively measured in the septum and left ventricular posterior wall using a quantitative IB imaging system to assess the alterations in the acoustic properties of myocardium associated with acute cardiac allograft rejection. The study population consisted of 23 cardiac allograft recipients and 18 normal subjects. In each cardiac allograft recipient, one to eight (mean, four) IB studies were performed, each within 24 hours of right ventricular endomyocardial biopsy performed for rejection surveillance. The magnitude of the cyclic variation of IB in the posterior wall was 5.9 +/- 0.9 dB in normal subjects and 6.2 +/- 1.3 dB in the cardiac allograft recipients without previous or current histological evidence of acute rejection (n = 17, p = NS vs. normal subjects). The magnitude of cyclic variation of IB in the septum was 4.8 +/- 1.1 dB in normal subjects and 3.8 +/- 2.0 dB in the cardiac allograft recipients (n = 15, p = NS vs. normal subjects). A significant decrease in the septal IB measure was observed in cardiac allograft recipients with left ventricular hypertrophy (wall thickness of at least 13 mm) (2.6 +/- 1.7 dB, n = 8, p less than 0.05 vs. normal subjects). IB studies were done before and during moderate acute rejection in 11 recipients (14 episodes). During moderate acute cardiac rejection, the magnitude of the cyclic variation in IB decreased from 6.7 +/- 1.3 to 5.1 +/- 1.4 dB in the posterior wall (n = 14, p less than 0.05) and from 4.2 +/- 2.1 dB to 2.9 +/- 1.8 dB in the septum (n = 12, p less than 0.05). These data suggest 1) the magnitude of the cyclic variation in IB of the septum is different in cardiac allografts with cardiac hypertrophy and normal subjects, possibly reflecting regionally depressed myocardial contractile performance and 2) acute cardiac rejection in humans is accompanied by an alteration in the acoustic properties of the myocardium. This change is detectable by serial measurement of the magnitude of the cyclic variation in IB, both in the septum and in the posterior wall.
منابع مشابه
Quantitative ultrasonic tissue characterization with real-time integrated backscatter imaging in normal human subjects and in patients with dilated cardiomyopathy.
We have shown previously that the physical properties of myocardium in dogs can be characterized with quantitative ultrasonic integrated backscatter and that interrogation of the tissue with ultrasound can delineate cardiac cycle-dependent changes in ultrasonic backscatter in normal tissue that disappear with ischemia and reappear with reperfusion if functional integrity is restorable. To deter...
متن کاملDIAGNOSTIC METHODS ULTRASOUND Quantitative ultrasonic tissue characterization with real-time integrated backscatter imaging in normal human subjects and in patients with dilated cardiomyopathy*
We have shown previously that the physical properties of myocardium in dogs can be characterized with quantitative ultrasonic integrated backscatter and that interrogation of the tissue with ultrasound can delineate cardiac cycle-dependent changes in ultrasonic backscatter in normal tissue that disappear with ischemia and reappear with reperfusion if functional integrity is restorable. To deter...
متن کاملEffects of myocardial ischemia on quantitative ultrasonic backscatter and identification of responsible determinants.
Quantitative characterization of myocardial properties represent a rapidly emerging area of echocardiographic investigation. Because measurement of the ultrasonic integrated backscatter is theoretically applicable to analysis in vivo with reflected ultrasound, this study was performed to develop and evaluate a suitable method for measurement of quantitative backscatter in vivo. In view of the d...
متن کاملUltrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients.
We have previously shown in studies of experimental animals that myocardium exhibits a cardiac cycle-dependent variation of integrated backscatter that reflects regional myocardial contractile performance and that is blunted promptly after arterial occlusion and recovers after reperfusion. To define the clinical utility of ultrasonic tissue characterization with integrated backscatter for detec...
متن کاملUltrasonic backscatter and collagen in normal ventricular myocardium.
Integrated ultrasonic backscatter has been related to collagen deposition in fibrotic myocardium. The purpose of our study was to measure the integrated ultrasonic backscatter in the right and left ventricles of 10 normal freshly excised canine hearts and five normal formalin-fixed human hearts. A 2.25 MHz, 50% fractional bandwidth transducer was positioned at the transducer focal distance from...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 81 3 شماره
صفحات -
تاریخ انتشار 1990