A D-Shaped Bileaflet Bioprosthesis which Replicates Physiological Left Ventricular Flow Patterns
نویسندگان
چکیده
Prior studies have shown that in a healthy heart, there exist a large asymmetric vortex structure that aids in establishing a steady flow field in the left ventricle. However, the implantation of existing artificial heart valves at the mitral position is found to have a negative effect on this physiological flow pattern. In light of this, a novel D-shaped bileaflet porcine bioprosthesis (GD valve) has been designed based on the native geometry mitral valve, with the hypothesis that biomimicry in valve design can restore physiological left ventricle flow patterns after valve implantation. An in-vitro experiment using two dimensional particle velocimetry imaging was carried out to determine the hemodynamic performance of the new bileaflet design and then compared to that of the well-established St. Jude Epic valve which functioned as a control in the experiment. Although both valves were found to have similar Reynolds shear stress and Turbulent Kinetic Energy levels, the novel D-shape valve was found to have lower turbulence intensity and greater mean kinetic energy conservation.
منابع مشابه
Experimental Validation of a Cardiac Simulator for in vitro Evaluation of Prosthetic Heart Valves
OBJECTIVE This work describes the experimental validation of a cardiac simulator for three heart rates (60, 80 and 100 beats per minute), under physiological conditions, as a suitable environment for prosthetic heart valves testing in the mitral or aortic position. METHODS In the experiment, an aortic bileaflet mechanical valve and a mitral bioprosthesis were employed in the left ventricular ...
متن کاملEffects of Bileaflet Mechanical Mitral Valve Rotational Orientation on Left Ventricular Flow Conditions
We studied left ventricular flow patterns for a range of rotational orientations of a bileaflet mechanical heart valve (MHV) implanted in the mitral position of an elastic model of a beating left ventricle (LV). The valve was rotated through 3 angular positions (0, 45, and 90 degrees) about the LV long axis. Ultrasound scans of the elastic LV were obtained in four apical 2-dimensional (2D) imag...
متن کاملLeft ventricular rupture following mitral valve replacement with a Hancock bioprosthesis.
A rare complication of mitral valve replacement with the Hancock bioprosthesis was observed in three patients presenting with prevalent mitral stenosis and normally-sized left ventricular cavity. In the patients, a deep erosion of the left ventricular free wall was present which evolved into cardiac rupture in one of them. The laceration is ascribed to the friction between a prosthetic strut an...
متن کاملHemodynamic Flow Characterization of St. Jude Medical Bileaflet Mechanical and Bioprosthetic Heart Valve Prostheses in a Left Ventricular Model via Digital Particle Image Velocimetry
متن کامل
Left ventricular phosphorylation patterns of Akt and ERK1/2 after triiodothyronine intracoronary perfusion in isolated hearts and short-term in vivo treatment in Wistar rats
Objective(s): To determine the effects of triiodothyronine (T3) intracoronary perfusion in isolated hearts and short-term administration in rats on the left ventricular (LV) phosphorylation patterns of Akt and ERK1/2. Materials and Methods: Cardiodynamic and hemodynamic parameters were evaluated in Langendorff–perfused hearts. Left ventr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016