Accelerated high-resolution differential ion mobility separations using hydrogen.

نویسندگان

  • Alexandre A Shvartsburg
  • Richard D Smith
چکیده

The resolving power of differential ion mobility spectrometry (FAIMS) was dramatically increased recently by carrier gases comprising up to 75% He or various vapors, enabling many new applications. However, the need for resolution of complex mixtures is virtually open-ended and many topical analyses demand yet finer separations. Also, the resolving power gains are often at the expense of speed, in particular making high-resolution FAIMS poorly compatible with online liquid-phase separations. Here, we report FAIMS employing hydrogen, specifically in mixtures with N(2) containing up to 90% H(2). Such compositions raise the mobilities of all ions and thus the resolving power beyond that previously feasible, while avoiding the electrical breakdown inevitable in He-rich mixtures. The increases in resolving power and ensuing peak resolution are especially significant at H(2) fractions above ~50%. Higher resolution can be exchanged for acceleration of the analyses by up to ~4 times. For more mobile species such as multiply charged peptides, this exchange is presently forced by the constraints of existing FAIMS devices, but future designs optimized for H(2) should consistently improve resolution for all analytes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential ion mobility separations in up to 100% helium using microchips.

The performance of differential IMS (FAIMS) analyzers is much enhanced by gases comprising He, especially He/N2 mixtures. However, electrical breakdown has limited the He fraction to ~50%-75%, depending on the field strength. By the Paschen law, the threshold field for breakdown increases at shorter distances. This allows FAIMS using chips with microscopic channels to utilize much stronger fiel...

متن کامل

Electrospray ionization high-resolution ion mobility spectrometry-mass spectrometry.

A hybrid atmospheric pressure ion mobility spectrometer is described which exhibits resolving power approaching the diffusion limit for singly and multiply charged ions (over 200 for the most favorable case). Using an electrospray ionization source and a downstream quadrupole mass spectrometer with electron multiplier as detector, this ESI-IMS-MS instrument demonstrates the potential of IMS for...

متن کامل

Lipid and Glycolipid Isomer Analyses Using Ultra-High Resolution Ion Mobility Spectrometry Separations

Understanding the biological roles and mechanisms of lipids and glycolipids is challenging due to the vast number of possible isomers that may exist. Mass spectrometry (MS) measurements are currently the dominant approach for studying and providing detailed information on lipid and glycolipid presence and changes. However, difficulties in distinguishing the many structural isomers, due to the d...

متن کامل

Separation of sodiated isobaric disaccharides and trisaccharides using electrospray ionization-atmospheric pressure ion mobility-time of flight mass spectrometry.

A series of isobaric disaccharide-alditols, four derived from O-linked glycoproteins, and select trisaccharides were rapidly resolved using tandem high resolution atmospheric pressure ion-mobility time-of-flight mass spectrometry. Electrospray ionization was used to create the gas-phase sodium adducts of each carbohydrate. Using this technique it was possible to separate up to three isobaric di...

متن کامل

Application of Differential Ion Mobility Mass Spectrometry to Peptide Quantitation Using SelexIONTM Differential Mobility Separation Technology for better selectivity for peptides in complex mixtures on the AB SCIEX Triple QuadTM 5500 LC/MS/MS System

 Reduced recovery, low sensitivity – The adsorptive properties and/or polarity of peptides can compromise recovery, and interferences from biological matrices can negatively impact sensitivity and selectivity.  Limited quantitation range – Poor MS/MS sensitivity combined with often poor selectivity can compromise the desired lower limits of quantitation (LLOQ).  Limited MRM selectivity – MRM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 83 23  شماره 

صفحات  -

تاریخ انتشار 2011