BIF Profile Monitor for the UNILAC - Tests and DAQ Upgrade
نویسندگان
چکیده
The non-intercepting Beam Induced Fluorescence (BIF) monitor for transverse beam profile measurements was successfully tested for different ion species and energies from 5 to 750 MeV/u at the GSI accelerators [1]. Starting from its first implementation [2] we systematically investigated technical aspects such as the proper choice of optics and gain factors, as well as physical aspects like the dependency of beam energy and ion species on signal amplitude and the signal to background ratio. Investigations of the wavelength spectrum have shown that unwanted profile distortions by 2-step excitation processes have negligible contributions to the total photon yield [3]. At the UNILAC X2 experimental area a pressure dependent measurement was performed. With a regulated needle valve we changed the N2 residual gas pressure from 10 to 10 mbar. Assuming constant beam parameters and within 1.6 σ according the fit function, the signal amplitude increases linearly with the gas pressure, while the profile width remains constant, as shown in Figure 1. Therefore the residual gas pressure can be used as a free parameter to match the required signal strength. Latest simulations of N+2 trajectories in the electrical field of the beam show negligible profile distortions, even for highest beam intensities in the upgraded UNILAC. For improved reliability, user-friendly operation and enhancend functional range, the DAQ-system and software are substantially upgraded.
منابع مشابه
Commissioning of Beam Induced Fluorescence Monitor at Unilac
Overview Due to the high-current operation at UNILAC nonintercepting beam diagnostics is mandatory. In October 2008 a Beam Induced Fluorescent (BIF) monitor for transverse profile determination was set up in the UNILAC section US1. It serves as a prototype for the installation at 7 locations at UNILAC and the transfer channel to SIS. The comissioning and proof of functionality of the new instal...
متن کاملBIF Monitor and RGM System Development for FAIR
Beam Induced Fluorescence Monitor Due to the high beam power expected for FAIR, novel methods for non-intersecting beam diagnostics for the High Energy Beam Transport Lines must be considered. We investigate the detection of fluorescence photons from the excited states of the residual gas N2 with a Beam Induced Fluorescence (BIF) Monitor [1]. This method was successfully applied for high curren...
متن کاملImaging-Spectroscopy for BIF-Monitors in Rare Gases and Nitrogen
For transverse profile determination a non-intercepting Beam Induced Fluorescence (BIF)-monitor was developed. The BIF-monitor detects fluorescence light emitted by residual gas molecules after atomic collisions with beam ions [1]. Using an imaging spectrograph the spectral response was mapped and associated with the corresponding gas transitions in helium, argon, krypton, xenon and nitrogen. S...
متن کاملDØ Online Monitoring and Automatic DAQ Recovery
The DZERO experiment, located at the Fermi National Accelerator Laboratory, has recently started the Run 2 physics program. The detector upgrade included a new Data Acquisition/Level 3 Trigger system. Part of the design for the DAQ/Trigger system was a new monitoring infrastructure. The monitoring was designed to satisfy real-time requirements with 1-second resolution as well as nonreal-time da...
متن کاملNon-destructive Transverse Profile Measurement at UNILAC and SIS
The traditional determination of transverse beam profiles by secondary emission grids cannot be applied at the high current operation with up to 20 mA for the full UNILAC macro-pulse length due to the large energy release in the material. Moreover, the spatial resolution is limited by the wire spacing of about 1 mm. To be able to measure the full pulse length, the fluorescence of the residual g...