Preoperative T Staging of Potentially Resectable Esophageal Cancer: A Comparison between Free-Breathing Radial VIBE and Breath-Hold Cartesian VIBE, with Histopathological Correlation12

نویسندگان

  • Fengguang Zhang
  • Jinrong Qu
  • Hongkai Zhang
  • Hui Liu
  • Jianjun Qin
  • Zhidan Ding
  • Yin Li
  • Jie Ma
  • Zhongxian Zhang
  • Zhaoqi Wang
  • Jianwei Zhang
  • Shouning Zhang
  • Yafeng Dong
  • Robert Grimm
  • Ihab R. Kamel
  • Hailiang Li
چکیده

PURPOSE To compare the T staging of potentially resectable esophageal cancer using free-breathing radial VIBE (r-VIBE) and breath-hold Cartesian VIBE (C-VIBE), with pathologic confirmation of the T stage. MATERIALS AND METHODS Fifty patients with endoscopically proven esophageal cancer and indeterminate T1/T2/T3 stage by CT scan were examined on a 3-T scanner. The MRI protocol included C-VIBE at 150 seconds post-IV contrast, immediately followed by a work-in-progress r-VIBE with identical spatial resolution (1.1 mm × 1.1 mm × 3.0 mm). Two independent readers assigned a T stage on MRI according to the 7th edition of UICC-AJCC TNM Classification, and postoperative pathologic confirmation was considered the gold standard. Interreader agreement was also calculated. RESULTS The T staging agreement between both VIBE techniques and postoperative pathologic T staging was 52% (26/50) for C-VIBE, 80% (40/50) for r-VIBE for reader 1, and 50% (25/50), 82% (41/50) for reader 2, respectively. For the esophageal cancer with invading lamina propria, muscularis mucosae, or submucosa (T1 stage), r-VIBE achieved 86% (12/14) agreement for both readers 1 and 2. For invasion of muscularis propria (T2 stage), r-VIBE achieved 83% (25/30) for both readers 1 and 2, whereas for the invasion of adventitia (T3 stage), r-VIBE could only achieve agreement in 50% (3/6) and 67% (4/6) for readers 1 and 2, respectively. CONCLUSION Contrast-enhanced free-breathing r-VIBE is superior to breath-hold CVIBE in T staging of potentially resectable esophageal cancer, especially for T1 and T2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Cartesian versus radial acquisition: comparison of two sequences for hepatobiliary phase MRI at 3 tesla in patients with impaired breath-hold capabilities

BACKGROUND Hepatocyte-specific gadolinium based contrast agents (HSCA) provide substantial information for the classification of liver lesions in magnetic resonance imaging (MRI). However, breathing artifacts which reduce image quality and diagnostic confidence of hepatobiliary phase acquisitions are regularly observed in clinical routine. The aim of this study was to evaluate two approaches to...

متن کامل

Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration.

OBJECTIVE : To compare free-breathing radially sampled 3D fat suppressed T1-weighted gradient-echo acquisitions (radial volumetric interpolated breath-hold examination [VIBE]) with breath-hold (BH) and free-breathing conventional (rectilinearly sampled k-space) VIBE acquisitions for postcontrast imaging of the liver. MATERIALS AND METHODS : Eighteen consecutive patients referred for clinicall...

متن کامل

The Effects of Breathing Motion on DCE-MRI Images: Phantom Studies Simulating Respiratory Motion to Compare CAIPIRINHA-VIBE, Radial-VIBE, and Conventional VIBE

OBJECTIVE To compare the breathing effects on dynamic contrast-enhanced (DCE)-MRI between controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE), radial VIBE with k-space-weighted image contrast view-sharing (radial-VIBE), and conventional VIBE (c-VIBE) sequences using a dedicated phantom experiment. MATERIALS...

متن کامل

Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations.

OBJECTIVE The purposes of this study were to evaluate the feasibility of a free-breathing 3D gradient-recalled echo sequence with radial data sampling (radial 3D GRE) in abdominal MRI compared with a standard 3D GRE volumetric interpolated breath-hold examination (VIBE) sequence for imaging of cooperative patients and to perform a preliminary assessment in imaging of noncooperative patients. ...

متن کامل

High Spatiotemporal Resolution Dynamic Contrast-Enhanced MR Enterography in Crohn Disease Terminal Ileitis Using Continuous Golden-Angle Radial Sampling, Compressed Sensing, and Parallel Imaging.

OBJECTIVE The purpose of this article was to assess the feasibility of golden-angle radial acquisition with compress sensing reconstruction (Golden-angle RAdial Sparse Parallel [GRASP]) for acquiring high temporal resolution data for pharmacokinetic modeling while maintaining high image quality in patients with Crohn disease terminal ileitis. MATERIALS AND METHODS Fourteen patients with biops...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017