Geometry, time-dependent and failure properties of human meniscal attachments.

نویسندگان

  • Karen N Hauch
  • Diego F Villegas
  • Tammy L Haut Donahue
چکیده

Meniscectomies have been shown to lead to osteoarthritis and the success of meniscal replacements remains questionable. It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau at the horn locations. To aid in the development of meniscal replacements, the objectives of the current study were to determine the time-dependent and failure properties of human meniscal attachments. In contrast to the time-dependent tests, during uniaxial failure testing a charge-coupled video camera was used to document the local strain and linear modulus distribution across the surface of the attachments. The lateral attachments were statistically smaller in cross-sectional area and longer than the medial attachments. The anterior attachments were statistically longer and had a smaller cross-sectional area than the posterior attachments. From the stress relaxation tests, the load and stress relaxation rates of the medial anterior attachment were statistically greater than the medial posterior attachment. There were no significant differences in the creep, structural properties or the ultimate stress between the different attachments. Ultimate strain varied between attachments, as well as along the length of the attachment. Ultimate strain in the meniscus region (10.4+/-6.9%) and mid-substance region (12.7+/-16.4%) was smaller than the bony insertion region (32.2+/-21.5%). The lateral and anterior attachments were also found to have statistically greater strain than the medial and posterior attachments, respectively. The linear modulus was statistically weaker in the bony insertion region (69.7+/-33.7MPa) compared to the meniscus region (153+/-123MPa) and mid-substance region (195+/-121MPa). Overall the anterior attachments (169+/-130MPa) were also found to be statistically stronger than the posterior attachments (90.8+/-64.9MPa). These results can be used to help design tissue-engineered replacement menisci and their insertions and show the differences in material properties between attachments, as well as within an attachment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time dependent properties of bovine meniscal attachments: stress relaxation and creep.

It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau [Chen, M.I., Branch, T.P., et al., 1996. Is it important to secure the horns during lateral meniscal transplantation? A cadaveric study. Arthroscopy 12(2), 174-181; Alhalki, M.M., et al., 1999. How thre...

متن کامل

Failure properties and strain distribution analysis of meniscal attachments.

The menisci are frequently injured due to both degeneration and traumatic tearing. It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau. Therefore, the objectives of the current study were to (1) determine the failure properties of the meniscal horn attac...

متن کامل

Nanoindentation of the insertional zones of human meniscal attachments into underlying bone.

The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal body, allowing the menisci to assist in load transmission from the femur to th...

متن کامل

How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact ...

متن کامل

Consequences of tibial tunnel reaming on the meniscal roots during cruciate ligament reconstruction in a cadaveric model, Part 1: The anterior cruciate ligament.

BACKGROUND The current standard for treating complete tears of the anterior cruciate ligament (ACL) is reconstruction, which requires reaming a tibial tunnel. Based on recent anatomic and biomechanical studies, this reconstruction tunnel may cause injuries to the anterior meniscal root attachments. PURPOSE/HYPOTHESIS The purpose was to determine if injuries occurred to the anteromedial (AM) a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 2010