SAR and B1 Field in a Human Head Model for Birdcage, TEM and Microstrip Coils at 7T
نویسندگان
چکیده
Introduction: The advantage of high field MRI is high SNR which can increase image resolution or decrease acquisition time. However, there are some challenges, such as the RF wavelength effect and the power deposition in tissues. A comparison of three different volume coils loaded with the same spherical homogeneous phantom has been reported [1]. In order to mimic the B1 field distribution and SAR in a realistic human head, an anatomically accurate human head model was chosen for the comparison of Birdcage, TEM and Microstrip at 300MHz. Methods: Three volume coils, Birdcage, TEM and Micrsostrip at 300MHz were designed and modeled. All coils have identical length (21 cm) and inner diameter (26 cm). Each coil consists of 16 rungs. The shield diameters of Birdcage, TEM and Microstrip coils are 32cm, 32cm and 28cm respectively. Three identical capacitors were equally distributed at each rung of Birdcage coil. The same capacitors were also placed at the middle of each end ring segment for the Birdcage coil. The legs and the end rings of Birdcage are 10mm width. The cross section of each rung of TEM coil is 10mm x 10mm square and the strip width of Microstrip coil is 20mm. The finite-difference time-domain (FDTD) method is used to calculate the transient B1 fields using XFDTD software (Remcom, Inc., State College, PA). These three volume coils were modeled with 5mm isotropic resolution. Copper was modeled as a conductor with conductivity of 5.95x10 S/m and capacitors were treated as passive loads. Tuning was performed by changing the capacitance for birdcage coil, by lengthening or shortening the inner conductors of the rungs for TEM and by changing the relative permittivity of dielectric materials for Microstrip coil. All these volume coils are tuned to 300MHz and driven in quadrature by two current sources. Two different samples, a spherical phantom and human head model are used for simulation. The spherical phantom has 18cm diameter which relative permittivity is 51.898 and conductivity is 0.553 S/m to represents average brain tissue at 300MHz. The home-made anatomically-accurate human head model was chosen from the Visible Human Project (National Library of Medicine, http://www.brooks.af.mil/AFRL/HEAD/hedr/). SAR was calculated after solving their electrical fields in the samples. Circularly-polarized components of the B1 field (B1 + and B1 ) were calculated from two sets of transient B1 fields which are a quarter period apart in time[2][3]. Results and Discussion: For comparison, the B1 + field magnitudes at the center of coils are normalized to 100%. When loaded with the spherical phantom, the percentages of sample on the central axial plane having a B1 + field magnitude within ±20% of that plane mean are 55%, 72% and 59% for shielded Birdcage, TEM and Microstrip volume coils respectively. The central axial planes in the modeled Birdcage, TEM and Microstrip volume coils loaded with the anatomically accurate human head model were shown in Fig. 1(top), and the B1 + field magnitudes on these central axial planes in the head model were shown in Fig.1 (bottom). Note that in Fig. 1(bottom), the B1 + field magnitudes outside the head model were truncated to zero. The dielectric resonance phenomenon is visible. The percentages of the samples on the central axial plane of the head model having a B1 + field magnitude within ±20% of the average B1 + field magnitude on that plane are 63%, 78% and 64% for Birdcage, TEM and Microstrip coils respectively. The results indicate that TEM coil has the best B1 + field homogeneity when loaded with the spherical phantom or the head model. Compared with the results by using the uniform spherical phantom, the B1 + field homogeneity in head model increases more than 5%. One of the reasons is that the dielectric effect in the spherical phantom is stronger than that in the head model. It may be caused by the complex tissues within the head model. Average SAR and maximum local SAR in the spherical phantom and the head model for Birdcage, TEM and microstrip volume coils are shown in Table 1. Microstrip volume coil has the lowest average SAR and the lowest maximum local SAR because its electric fields are mainly restricted between strip line and ground. Compared with the results by using spherical phantom, the average SAR in the head model is slightly higher than those in the spherical phantom and the maximum local SAR in the head model increase dramatically. The reason may lie in that there are some tissues having much higher conductivity in head model than the average brain tissue in the spherical phantom. The local SAR distributions on the central axial plane through head model for the RF coils were shown in Fig 2. The black holes at the anteriority of the head models in Fig 2 are areas of internal air. The local SAR at the periphery of brain is much higher than that in the middle of brain. It is caused by that the electric filed at the periphery of head model is stronger than that in the middle of the head model.
منابع مشابه
Numerical Comparison Between TEM Head Coil and Birdcage Head Coil at 7T
G. D. DeMeester, Z. Zhai, M. A. Morich, C. Leussler, C. Findeklee Philips Medical Systems, Cleveland, Ohio, United States, Philips Research Laboratories, Hamburg, Hamburg, Germany Introduction A TEM T/R head coil and a shielded birdcage T/R head coil operated at 298MHz/7T were both modeled using the Finite Difference Time Domain (FDTD) method. The two coils have approximately the same physical ...
متن کاملComparison of B1 Field Homogeneity for Shielded Birdcage, TEM and Microstrip Volume Coils at 300MHz
Introduction: Because of the inherent advantage of improved SNR, ultra-high field (3T~9.4T) MRI technology and applications have been accelerated these years. However many engineering challenges have arisen from high-operation frequencies. One major challenge is the difficulty of designing large-size RF coils with high-resonance frequencies. In addition, it has been shown that the homogeneity o...
متن کاملDouble Tuned 31P/1H Elliptical Transceiver Phased Array for the Human Brain Studies at 7 T
Introduction: The improved SNR at 7T provides significant advantages for both H and lower gyromagnetic nuclei such as P, Na and C (X nuclei). Double resonant volume head coils, based on both birdcage (1-3) and TEM (4) designs have been previously used at lower magnetic fields. However at 7T, transceiver phased arrays provide significant advantages for both B1 homogeneity and transmit efficiency...
متن کاملTowards the Optimum 7T Head RF Coil
G. McKinnon, E. Boskamp GE Medical Systems, Waukesha, WI, United States Introduction Numerical simulations were used in an attempt to find the optimal configuration for a 7T head coil. The high-pass birdcage, the hybrid birdcage, and the TEM resonator were compared. The coil dimensions were kept as similar as possible. Performance was evaluated on the basis of normalized peak E field, SNR and B...
متن کاملA 7T 8 channel transmit-receive dipole array for head imaging: dipole element and coil evaluation
Target audience: Radiofrequency (RF) engineers, anyone interested in high field RF coils, parallel transmit or high field brain imaging. Introduction: Electric dipole antennas are seeing increasing use for 7T MR imaging. They differ from conventional surface coil loops in many ways. With 8 elements surrounding a body sized tissue equivalent phantom and array of dipole antennas can achieve highe...