Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200)

نویسندگان

  • A John Kanellopoulos
  • George Asimellis
چکیده

PURPOSE To evaluate programmed versus achieved laser-assisted in situ keratomileusis (LASIK) flap central thickness and investigate topographic flap thickness variability, as well as the effect of potential epithelial remodeling interference on flap thickness variability. PATIENTS AND METHODS Flap thickness was investigated in 110 eyes that had had bilateral myopic LASIK several years ago (average 4.5 ± 2.7 years; range 2-7 years). Three age-matched study groups were formed, based on the method of primary flap creation: Group A (flaps made by the Moria Surgical M2 microkeratome [Antony, France]), Group B (flaps made by the Abbott Medical Optics IntraLase™ FS60 femtosecond laser [Santa Ana, CA, USA]), and Group C (flaps made by the Alcon WaveLight(®) FS200 femtosecond laser [Fort Worth, TX, USA]). Whole-cornea topographic maps of flap and epithelial thickness were obtained by scanning high-frequency ultrasound biomicroscopy. On each eye, topographic flap and epithelial thickness variability was computed by the standard deviation of thickness corresponding to 21 equally spaced points over the entire corneal area imaged. RESULTS The average central flap thickness for each group was 138.33 ± 12.38 μm (mean ± standard deviation) in Group A, 128.46 ± 5.72 μm in Group B, and 122.00 ± 5.64 μm in Group C. Topographic flap thickness variability was 9.73 ± 4.93 μm for Group A, 8.48 ± 4.23 μm for Group B, and 4.84 ± 1.88 μm for Group C. The smaller topographic flap thickness variability of Group C (FS200) was statistically significant compared with that of Group A (M2) (P = 0.004), indicating improved topographic flap thickness consistency - that is, improved precision - over the entire flap area affected. CONCLUSIONS The two femtosecond lasers produced a smaller flap thickness and reduced variability than the mechanical microkeratome. In addition, our study suggests that there may be a significant difference in topographic flap thickness variability between the results achieved by the two femtosecond lasers examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome.

PURPOSE To evaluate the thickness and side-cut angle of laser in situ keratomileusis (LASIK) flaps created by 1 of 3 femtosecond lasers or a microkeratome using Fourier-domain optical coherence tomography (OCT). SETTING Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea. DESIGN Comparative case series. METHODS Flap creation for b...

متن کامل

Comparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome.

AIM To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-µm-thick corneal flap and to identify the potential factors that affect corneal flap thickness. METHODS A prospective case study was performed on 120 eyes of 60 patients who were divided into two groups for LASIK, each group consisting ...

متن کامل

Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography.

PURPOSE To assess and compare the morphology of laser in situ keratomileusis flaps (LASIK) created by a 60 kHz femtosecond laser and a mechanical microkeratome. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS Anterior segment optical coherence tomography (AS-OCT) (Visante) was used to assess 1 week postoperatively the morphology of...

متن کامل

Predictability of Corneal Flap Thickness in LASIK Using the WaveLight FS200 Femtosecond Laser

250 of 250 words) Purpose: To compare the intended versus resultant thickness of laser in situ keratomileusis (LASIK) flaps created with a new femtosecond laser (WaveLight FS200 Femtosecond Laser, WaveLight GmbH, Alcon Laboratories) and to report refractive outcomes at 3 months posttreatment. Setting: Wellington Eye Clinic, Dublin, Ireland Design: Retrospective consecutive case series Methods: ...

متن کامل

Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform

BACKGROUND The purpose of this study was to evaluate the safety and efficacy of topography-guided ablation using the WaveLight 400 Hz excimer laser in laser-assisted in situ keratomileusis (LASIK) for hyperopia and/or hyperopic astigmatism. METHODS We prospectively evaluated 208 consecutive LASIK cases for hyperopia with or without astigmatism using the topography-guided platform of the 400 H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013