Bone ingrowth into madreporic prostheses.

نویسنده

  • M P Barbos
چکیده

Three madreporic prostheses in two patients were examined to evaluate resorption and formation of the surrounding bone tissue. All three prostheses were firmly fixed and had no clinical or radiographic signs of loosening. Transverse sections were examined by scanning electron microscopy at 40 days, 11 months and 2.5 years after implantation. The findings suggest that adaptive bone remodelling varies along the length of the stem; that bone resorption and formation are related to the time after implant; and that new bone formation (woven bone) can be found very close to the madreporic surface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hydroxyapatite Coated Collar Reduces Aseptic Loosening of Cemented Distal Femoral Massive Bone Tumour Prostheses

Background: Aseptic loosening of massive bone tumour implants remains one of the major causes of prosthesis failure. Question: The hypothesis of this study was that an osteointegrated hydroxyapatite (HA) coated collar would reduce the incidence of aseptic loosening around the cemented intramedullary stem in distal femoral bone tumour prostheses. Methods: Twenty-two patients were pair matched in...

متن کامل

In vivo testing of porous Ti-25Nb alloy serving as a femoral stem prosthesis in a rabbit model

The aim of the present study was to observe the performance of Ti-25Nb alloys with various porosities as femoral stem prostheses in a rabbit model, thus providing basic experimental evidence for the development of porous prostheses. The porous Ti-25Nb alloy prostheses were designed according to the morphology of the medullary cavity. These prostheses were placed into the femoral medullary cavit...

متن کامل

Porous implants as drug delivery vehicles to augment host tissue integration.

The common premise of synthetic implants in the restoration of diseased tissues and organs is to use inert and solid materials. Here, a porous titanium implant was fabricated for the delivery of microencapsulated bioactive cues. Control-released transforming growth factor-beta1 (TGF-beta1) promoted the proliferation and migration of human mesenchymal stem cells into porous implants in vitro. At...

متن کامل

The Metal-Cancellous Cementless Lübeck total hip arthroplasty. Five-to-nine-year results.

We implanted 51 Metal-Cancellous Cementless Lübeck (MCCL) prostheses into 45 patients with dysplastic hips and followed 49 hips (96.1%) for five to nine years. One had needed revision for stem fracture and one for infection; the clinical outcome of the other 47 hips was assessed using the Merle d'Aubigné and Postel hip score. All hips were either excellent (63%) or good (37%). Three patients (6...

متن کامل

Radiologic Evaluation of Compressive Osseointegration for the Fixation of Reconstruction Prostheses after Tumor Resection

OBJECTIVE In pursuance of thoroughly understanding and facilitating the evaluation of the radiological changes in the preloaded bone by Compliant Pre-Stress osseointegration (Compress Biomet, Warsaw, Indiana) a new staging method was created depicting four stages. METHODS Two cohorts (10 and 17 patients resp., not-receiving and receiving chemotherapy) were compared in terms of progression of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 1988