Out-of-hospital cardiopulmonary resuscitation with the AutoPulse system: a prospective observational study with a new load-distributing band chest compression device.
نویسندگان
چکیده
OBJECTIVE To evaluate the effectiveness, the safety, and the practicability of the new automated load-distributing band resuscitation device AutoPulse in out-of-hospital cardiac arrest in the midsized urban emergency service of Bonn city. STUDY DESIGN Prospective, observational study. METHODS Measurements of effectiveness were the proportion of patients with a return of spontaneous circulation (ROSC) and end-tidal carbon-dioxide (etCO(2)) values during cardiopulmonary resuscitation (CPR). The indications of safety was the proportion of injuries caused by the device, and practicability was assessed by the measurement of the time taken to setup the AutoPulse. RESULTS Forty-six patients were resuscitated with the device from September 2004 to May 2005. In 25 patients (54.3%) ROSC was achieved, 18 patients (39.1%) were admitted to intensive care unit (ICU), and 10 patients (21.8%) were discharged from ICU. End-tidal capnography showed significantly higher etCO(2) values in patients with ROSC than in patients without ROSC. The mean time to setup the AutoPulse was 4.7+/-5.9 min, but activation of the device after arrival at the scene in 2 min or less was possible in 67.4%. No injuries were detected after use of the AutoPulse-CPR. CONCLUSION The AutoPulse system is an effective and safe mechanical CPR device useful in out-of-hospital cardiac arrest CPR. Automated CPR devices may play an increasingly important role in CPR in the future because they assure continuous chest compressions of a constant quality.
منابع مشابه
Improved hemodynamics with a novel chest compression device during treatment of inhospital cardiac arrest
Introduction Previous research has shown that increased coronary perfusion pressure (CPP) during cardiopulmonary resuscitation (CPR) correlates with increased coronary blood flow and improved survival from sudden cardiac arrest. The purpose of this clinical study was to determine if a novel chest compression device (AutoPulse, Revivant Corp) improves hemodynamics during CPR when compared with m...
متن کاملLoad-distributing-band cardiopulmonary resuscitation for out-of-hospital cardiac arrest increases regional cerebral oxygenation: a single-center prospective pilot study
BACKGROUND Despite advances in therapeutic strategies and improved guidelines, morbidity and mortality rates for out-of-hospital cardiac arrest (OHCA) remain high. Especially, neurological prognosis is one of the most important problems even though brain protection therapy for patients with OHCA has improved greatly in recent years due to the development of emergency post-cardiac arrest interve...
متن کاملEnd-tidal CO2 in mechanical versus conventional CPR
Introduction Out-of-hospital cardiac arrest (OHCA) generally has a poor prognosis. The development and use of a mechanical chest compression device has been suggested as a measure to achieve sufficient and continuous cardiopulmonary resuscitation (CPR). The mechanical chest compression device (Autopulse®) consists of a battery-driven board with a band attached that applies a 20% anteriorposteri...
متن کاملCardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: improved hemodynamics and mechanisms.
OBJECTIVES The goal of this study was to determine the magnitude and mechanisms of hemodynamic improvement of an automated, load-distributing band device (AutoPulse, Revivant Corp., Sunnyvale, California) compared with conventional cardiopulmonary resuscitation (C-CPR). BACKGROUND Improved blood flow during cardiopulmonary resuscitation (CPR) enhances survival from cardiac arrest. METHODS A...
متن کامل1036. Comparison of the hemodynamic parameters of two external chest compression devices (LUCAS versus AUTOPULSE) in a swine model of ventricular fibrillation
Introduction Given the difficulty of performing efficient CPR compressions, technology has turned to automaticity. LUCAS device has a pneumatically driven piston to compress the heart and uses active decompression suction on the upstroke. AUTOPULSE is a load distributing band compressor, that is mechanically actuated and battery driven. It provides both direct compression and semi-circumferenti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Resuscitation
دوره 73 1 شماره
صفحات -
تاریخ انتشار 2007