Characterization of Tympanic Cavity Volume in Newborns using Computerized Tomography Scanning
نویسندگان
چکیده
This study reports tympanic cavity (TC) volume in newborns, which was missing in the literature. Ex vivo histology and computerized tomography (CT) scans were performed on temporal bone and data were analyzed in part using software developed in house. CT images with a slice thickness of 0.5 mm were obtained from 5 newborn cadavers and analyzed independently by two expert researchers. The border of the TC was delineated manually and measurement of area of interest was calculated on masked images. Then, the area measurements from all sections were added to estimate the total volume. The agreements between the histological and CT findings were then compared for accuracy, repeatability and reliability. The Dice and Jaccard similarity coefficient measures were used as a statistical validation metric to evaluate the assessor’s performance in manual volume segmentation. Good assessor agreement was observed with average Dice values above 0.8 indicating that consistent and reliable volume measurements were feasible. The proposed protocol was shown to be accurate in calculating the TC volume, and thus can be used for computer-assisted presurgical planning or for diagnosing structural alterations in TC.
منابع مشابه
Volume rendering of the tympanic cavity from micro-CT data.
The current study presents volumetric reconstruction of the tympanic cavity obtained from micro-CT scans which pixel size was 18 μm. Thanks to this, osseous components of the tympanic cavity were shown in high optical resolution, causing that their morphological appearance was clearly demonstrated. Particular attention was paid on imaging the medial wall of the tympanic cavity, because its stru...
متن کاملA nonlinear finite-element model of the newborn middle ear.
A three-dimensional static nonlinear finite-element model of a 22-day-old newborn middle ear is presented. The model includes the tympanic membrane (TM), malleus, incus, and two ligaments. The effects of the middle-ear cavity are taken into account indirectly. The geometry is based on a computed-tomography scan and on the published literature, supplemented by histology. A nonlinear hyperelastic...
متن کاملWideband Measurements in Newborns: Relationship to Otoscopic Findings
................................................................................................................ iii Résumé ................................................................................................................... v Acknowledgments .............................................................................................. viii List of figures ..........................
متن کاملComparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction.
BACKGROUND Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. OBJECTIVES This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of...
متن کاملTotal mastoid obliteration in staged canal-up tympanoplasty for cholesteatoma facilitates tympanic aeration.
OBJECTIVE To assess middle ear aeration after total mastoid obliteration using bone pate and hydroxyapatite performed at the second stage of intact-canal-wall (ICW) tympanoplasty. STUDY DESIGN Retrospective study. SETTING Tertiary referral hospital. PATIENTS Forty-two ears with cholesteatoma underwent the obliteration. Computed tomography (CT) scan 1 week before the second-stage operation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016