Experimental anterior chamber maintenance in active versus passive phacoemulsification fluidics systems.
نویسندگان
چکیده
PURPOSE To evaluate the ability of phacoemulsifiers with active versus passive infusion fluidics control systems to maintain target intraocular pressures (IOPs) under varying flow conditions. SETTING Alcon Research, Ltd., Lake Forest, California, USA. DESIGN Experimental study. METHODS An acrylic test chamber was used to model the anterior chamber of the eye. Two passive (gravity-based) systems were tested using bottle heights yielding infusion pressures of 41, 75, and 109 cm of water under zero-flow conditions. One actively controlled system was tested using equivalent target IOPs of 30, 55, and 80 mm Hg. Test chamber IOPs were measured at aspiration flow rates of 15, 30, 45, and 60 cc/min. RESULTS The measured flow rates were similar between fluidics systems across the range of intended aspiration flow rates. All systems achieved the desired target IOPs under zero-flow conditions. After activation of aspiration flow, however, measured IOPs decreased from target IOPs for the 2 passive systems. Each 15 cc/min increase in the aspiration flow rate produced a pressure drop of 14.0 to 16.2 mm Hg or 9.3 to 14.2 mm Hg, depending on the system. Measured IOPs in the actively controlled system closely matched the targeted IOPs across all tested aspiration flow rates, deviating from targets by no more than 4.3 mm Hg. CONCLUSIONS All phacoemulsification aspiration infusion fluidics systems achieved target IOPs under zero-flow conditions. Only the actively controlled system maintained target IOPs across a range of aspiration flow rates. These experimental findings suggest that anterior chamber stability might be better in the clinical setting using an actively controlled system. FINANCIAL DISCLOSURE Dr. Dimalanta is an employee of Alcon Research, Ltd. Dr. Miller is an investigator and speaker for and a consultant to Alcon Laboratories, Inc. Dr. Nicoli has no financial or proprietary interest in any material or method mentioned.
منابع مشابه
Cataract Surgery with a New Fluidics Control Phacoemulsification System in Nanophthalmic Eyes
PURPOSE To report visual outcomes and complications after cataract surgery in nanophthalmic eyes with a phacoemulsification system using the active fluidics control strategy. METHODS This is a retrospective case series. All eyes with an axial length of less than 20 mm that underwent cataract surgery or refractive lens exchange using the Centurion Vision System (Alcon Laboratories Inc.) in Hon...
متن کاملComparison of occlusion break responses and vacuum rise times of phacoemulsification systems
BACKGROUND Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. METHODS Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, ...
متن کامل[Prospective randomized trial comparing Discovisc versus Healon in phacoemulsification].
OBJECTIVE To compare the intraoperative behaviour of both, DisCoVisc and Healon used as viscoelastics in cataract surgery. METHOD We prospectively evaluated 35 patients with cataracts who underwent phacoemulsification and intraocular lens implantation. Patients were randomized into two groups. Group A included 17 patients in where Healon was used as a viscoelastic, whereas group B included 18...
متن کاملComparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device: Randomized controlled trial
AIM We conducted this study to evaluate and compare corneal endothelial cell loss between phacoemulsification with continuous anterior chamber infusion using anterior chamber maintainer (ACM) and phacoemulsification using ophthalmic viscosurgical device (OVD). MATERIALS AND METHODS This was a prospective, randomized controlled trial. Fifty eyes of 47 patients of senile cataract undergoing pha...
متن کاملOutcomes study between femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery using an active fluidics system
PURPOSE The purpose of this study was to compare intraoperative parameters between femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification using Centurion® Vision System with Active Fluidics. SETTING This study was performed at Brasília Ophthalmologic Hospital, Brasília, Federal District, Brazil. PATIENTS AND METHODS This was a prospective randomized compara...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2016