Development of semiconductor nanomaterial whole cell imaging sensor on glass slides.

نویسندگان

  • Hengyi Xu
  • Zoraida Pascual Aguilar
  • Hua Wei
  • Andrew Wang
چکیده

We report the development of a highly specific semiconductor quantum dots (QDs)-based whole cell imaging sensor that offer rapid, reproducible, accurate, and long term cell imaging system on silanized microscope glass slides. The QD-based imaging sensor involved capture of whole cells with QD labeled highly specific antibodies against over expressed cell membrane proteins. The QDs were first modified with a polymer coating to generate carboxyl groups on the surface. Using the carboxylated QDs, antibodies were covalent conjugated using carbodiimide chemistry to form 2(0)Ab~QD that were used to capture whole cell. The SK-BR3 cell line was used as a model analyte in the sandwich type assay consisting of 1(0)Ab + SK-BR3 + Ab' + 2(0)Ab~QD. The assay was immobilized on an antibody modified silanized microscope slide that was subsequently mounted on a fluorescence microscope for detection. The results indicated that the QD based imaging sensor exhibited brighter signals compared with organic dye Texas red. The QD-based whole cell imaging sensor was visible under the microscope even after one week without fixation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital Imaging in Cytopathology

Rapid advances are occurring in the field of cytopathology, particularly in the field of digital imaging. Today, digital images are used in a variety of settings including education (E-education), as a substitute to multiheaded sessions, multisite conferences, publications, cytopathology web pages, cytology proficiency testing, telecytology, consultation through telecytology, and automated scre...

متن کامل

Semantic Focusing Allows Fully Automated Single-Layer Slide Scanning of Cervical Cytology Slides

Liquid-based cytology (LBC) in conjunction with Whole-Slide Imaging (WSI) enables the objective and sensitive and quantitative evaluation of biomarkers in cytology. However, the complex three-dimensional distribution of cells on LBC slides requires manual focusing, long scanning-times, and multi-layer scanning. Here, we present a solution that overcomes these limitations in two steps: first, we...

متن کامل

Clinical Applications of Whole-slide Imaging in Anatomic Pathology.

The development of whole-slide imaging has paved the way for digitizing of glass slides that are the basis for surgical pathology. This transformative technology has changed the landscape in research applications and education but despite its tremendous potential, its adoption for clinical use has been slow. We review the various niche applications that initiated awareness of this technology, p...

متن کامل

Comparing whole slide digital images versus traditional glass slides in the detection of common microscopic features seen in dermatitis

BACKGROUND The quality and limitations of digital slides are not fully known. We aimed to estimate intrapathologist discrepancy in detecting specific microscopic features on glass slides and digital slides created by scanning at ×20. METHODS Hematoxylin and eosin and periodic acid-Schiff glass slides were digitized using the Mirax Scan (Carl Zeiss Inc., Germany). Six pathologists assessed 50-...

متن کامل

Development and use of a genitourinary pathology digital teaching set for trainee education

BACKGROUND Automated, high-speed, high-resolution whole slide imaging (WSI) robots are becoming increasingly robust and capable. This technology has started to have a significant impact on pathology practice in various aspects including resident education. To be sufficient and adequate, training in pathology requires gaining broad exposure to various diagnostic patterns through teaching sets, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Frontiers in bioscience

دوره 3  شماره 

صفحات  -