Transmissive x-ray beam position monitors with submicron position- and submillisecond time resolution.
نویسندگان
چکیده
We present the development of fast transmissive center-of-mass x-ray beam position monitors with a large active area, based on a thinned position sensitive detector in both a duo- and a tetra-lateral variant. The detectors were tested at BESSY beamlines BL14.1, KMC-1, and KMC-2 and yielded signal currents of up to 3 microA/100 mA ring current at 10 keV photon energy using the monochromatic focused beam of BL14.1. The active area sizes were 1 x 1 and 3 x 3 mm(2) for the duo-lateral and 5 x 5 mm(2) for the tetra-lateral devices, with the duo-lateral detectors currently being available in sizes from 1 x 1 to 10 x 10 mm(2) and thicknesses between 5 and 10 microm. The presented detectors' thicknesses were measured to be 5 and 8 microm with a corresponding transmission of up to 93% at 10 keV and 15% at 2.5 keV. Up to a detection bandwidth of 10 kHz, the monitors provide submicron position resolution. For lower detection bandwidths, the signal-to-noise reaches values of up to 6 x 10(4) at 10 Hz, corresponding to a position resolution of better than 50 nm for both detector sizes. As it stands, this monitor design approach promises to be a generic solution for automation of state-of-the-art crystal monochromator beamlines.
منابع مشابه
Cavity Beam Position Monitors
Beam-based alignment and feedback systems are essential for the operation of future linear colliders and free electron lasers. A certain number of beam position monitors with a resolution in the submicron range are needed at selected locations. Most beam position monitors detect the electric or the magnetic eld excited by a beam of charged particles at di erent locations around the beam pipe. I...
متن کاملOrbit Feedback Using X-ray Beam Position Monitoring at the Advanced Photon Source
The Advanced Photon Source (APS) was commissioned in 1995 as a third-generation x-ray user facility. At that time orbit control was performed exclusively with broadband rf beam position monitors (BPMs). Since then, emphasis has been placed on incorporating x-ray beam position monitors into the orbit control algorithms. This has resulted in an order of magnitude improvement in long-term beam sta...
متن کاملBeam Position Monitors Characterization for Alba
Beam position monitors (BPM) characterization has been widely studied at ALBA Synchrotron Light Source. Special care has been taken on the analysis of their electrical offset in order to achieve submicron beam stabilities. This paper shows the results of the BPM offset study for Booster and Storage Ring. The electrical effect of the different vacuum vessels housing the BPMs is also reported.
متن کاملComparison of Stripline and Cavity Beam Position Monitors
Operational principles of stripline and pill-box cavity beam position monitors (BPMs) are discussed. Their theoretically best achievable position and time resolutions are computed. Numbers are estimated using design values of the proposed e+e− linear collider TESLA. Introduction Important characteristics of a beam position monitor (BPM) are position and time resolutions. Position resolution is ...
متن کاملVery High Resolution Rf Cavity Bpm*
Linear collider (LC) interaction region beam sizes and component position stability requirements are expected to be a few nanometers[1]. It is important to show that the related tolerances can be achieved, with an electron beam if possible. Using recently developed component stabilization technology, very high-resolution beam position monitors (BPM’s), and the ultra-low emittance beam at the KE...