Harmonic Modelling of Distorting Loads on Distribution Feeders and in a Large Power System

نویسنده

  • M. Ghezelayagh V. J. Gosbell
چکیده

In most of frequency response type program, it is common to assume that all harmonic sources have the same phase angle. In this paper this assumption is investigated for distorting loads with diode rectifier front ends. Based on these investigation correct equivalent models of distorting loads are proposed firstly on one distribution feeder and secondly for distribution feeders in different subsystems of a large network. For the purpose of these investigations a Power Electronic Simulator (PES) with Time Domain solution has been used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new method based on fuzzy system and gravitational optimal detector for capacitor placement, considering nonlinear loads

This paper describes an advantageous method for using the capacitor banks in the distribution network, optimally. The aim is to determine the count, location and capacitor values in order to minimize the annual cost resulting from energy losses and capacitor bank’s installation cost. Besides, in the case of having nonlinear loads in the network, by installing capacitors in appropriate locations...

متن کامل

A New Procedure for Determining Current Harmonic Contribution around an Operation Point at PCC Using Load Modelling Based on Crossed Frequency Admittance Matrix

Abstract:Today, one of the important issues of power quality (PQ) in power systems is the current harmonics. Increasing expansion of nonlinear loads at different parts of the electric network makes harmonic distortion flow through the network. This causes the network to have background voltage and current harmonic distortion and even affect on the PQ of linear load performance. Therefore, it is...

متن کامل

Capacitor Placement in Distorted Distribution Network Subject to Wind and Load Uncertainty

Utilizing capacitor banks is very conventional in distribution network in order for local compensation of reactive power. This will be more important considering uncertainties including wind generation and loads uncertainty. Harmonics and non-linear loads are other challenges in power system which complicates the capacitor placement problem. Thus, uncertainty and network harmonics have been con...

متن کامل

An Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network

An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...

متن کامل

A %THD analysis of industrial power distribution systems with active power filter-case studies

Increasing use of variable speed drives in industry causes harmonic proliferation in industrial power distribution supply system. Harmonic currents generated by the variable speed drives interact with power system impedance to give rise to harmonic voltage distortion. Thus it is essential to analyze, evaluate and introduce appropriate mitigation techniques for harmonic reduction in the power sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002