OBJECTIVE This blind crossover study evaluates the effect of the number of electrodes of the Clarion CII cochlear implant on speech perception in silence and in noise using a "high-rate" continuous interleaved sampling (CIS) strategy. MATERIAL AND METHODS Nine users of this implant with 3-11 months of experience of an 8-channel CIS strategy [833 pulses per second (pps)/channel, 75 micros/phase] were fitted in a random order with 8-, 12- and 16-channel CIS strategies (+/- 1,400 pps/channel, 21 micros/phase). After 1 month of exclusive use of each strategy the performance was tested with consonant-vowel-consonant words in silence (sound only) and in speech-shaped background noise with signal-to-noise ratios (SNRs) of + 10, + 5, 0 and -5 dB. RESULTS With "high-rate" strategies most patients' speech understanding in noise improved, although the optimum number of electrodes was highly variable. Generally, faster performers benefited from more active electrodes, whilst slower performers deteriorated. If each patient's optimal strategy was determined by a weighted sum of the test results at +10, + 5 and 0 dB SNR, the average phoneme score improved from 57% to 72% at a SNR of + 5 dB, and from 46% to 56% at a SNR of 0 dB. The average phoneme score in silence was approximately 85% for all strategies. CONCLUSION We conclude that speech perception (especially in noise) can improve significantly with "high-rate" speech processing strategies, provided that the optimum number of electrodes is determined for each patient individually.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of stimulation rate on cochlear implant users' phoneme, word and sentence recognition in quiet and in noise.

High stimulation rates in cochlear implants (CI) offer better temporal sampling, can induce stochastic-like firing of auditory neurons and can increase the electric dynamic range, all of which could improve CI speech performance. While commercial CI have employed increasingly high stimulation rates, no clear or consistent advantage has been shown for high rates. In this study, speech recognitio...

متن کامل

SPAIDE: A Real-time Research Platform for the Clarion CII/90K Cochlear Implant

SPAIDE (sound-processing algorithm integrated development environment) is a real-time platform of Advanced Bionics Corporation (Sylmar, Calif, USA) to facilitate advanced research on sound-processing and electrical-stimulation strategies with the Clarion CII and 90K implants. The platform is meant for testing in the laboratory. SPAIDE is conceptually based on a clear separation of the sound-pro...

متن کامل

Place-pitch discrimination of single- versus dual-electrode stimuli by cochlear implant users (L).

Simultaneous or near-simultaneous activation of adjacent cochlear implant electrodes can produce pitch percepts intermediate to those produced by each electrode separately, thereby increasing the number of place-pitch steps available to cochlear implant listeners. To estimate how many distinct pitches could be generated with simultaneous dual-electrode stimulation, the present study measured pl...

متن کامل

Effect of Stimulation Rate on Cochlear Implant Users Phoneme, Word and Sentence Recognition in Quiet and in Noise

High stimulation rates in cochlear implants (CI) offer better temporal sampling, can induce stochastic-like firing of auditory neurons and can increase the electric dynamic range, all of which could improve CI speech performance. While commercial CI have employed increasingly high stimulation rates, no clear or consistent advantage has been shown for high rates. In this study, speech recognitio...

متن کامل

Radiological and Histological Evaluation of Perimodular Electrodes: Impact on Cochlear Implant Development

Introduction: Different Perimodiolar electrodes were developed by many cochlear implant (CI) manufacturers in the past few years. Possible advantages are lower stimulation thresholds and a better channel separation. A position close to the modiolus can be facilitated by different means: preformed electrode shape (Nucleus ContourTM electrode, Cochlear Corp., Australia), additional positioning el...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta oto-laryngologica

دوره 123 2  شماره 

صفحات  -

تاریخ انتشار 2003