Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model
نویسندگان
چکیده
OBJECTIVE To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA) stent. BACKGROUND As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. METHODS Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Biotechnology Co., Ltd., China) and eight metallic stents (EXCEL, Jiwei Co., Ltd. China) were implanted into coronary arteries. Upon quantitative coronary angiography analysis, acute absolute recoil was defined as the difference between mean diameter of inflated balloon (X) and mean lumen diameter of stent immediately after deployment (Y), while acute percent recoil was defined as (X-Y)/X and expressed as a percentage. Intravascular ultrasound (IVUS) was performed immediately after implantation and 24 hours later to compare cross-sectional area (CSA) between two groups and detect stent malapposition or collapse. RESULTS Acute absolute recoil in XINSORB and EXCEL was 0.02 ± 0.13 mm and -0.08 ± 0.08 mm respectively (P = 0.19). Acute percent recoil in XINSORB and EXCEL was 0.66 ± 4.32% and -1.40 ± 3.83%, respectively (P = 0.45). CSA of XINSORB was similar to that of EXCEL immediately after implantation, so was CSA of XINSORB at 24-hours followup. Within XINSORB group, no difference existed between CSA after implantation and CSA at 24-hours followup. No sign of acute stent malapposition was detected by IVUS. CONCLUSIONS The acute stent recoil of XINSORB is similar to that of EXCEL. No acute stent malapposition or collapse appeared in both kinds of stent. This preclinical study was designed to provide preliminary data for future studies of long-term efficacy and safety of XINSORB stent.
منابع مشابه
Late stent recoil of the bioabsorbable everolimus-eluting coronary stent and its relationship with plaque morphology.
OBJECTIVES This study sought to evaluate late recoil of a novel bioabsorbable everolimus-eluting coronary stent (BVS), which is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing everolimus. BACKGROUND Little is known about the mechanical behavior of bioabsorbable polymer stents after deployment in diseased human coronary arteries. METHODS The study po...
متن کاملInitial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans.
BACKGROUND Although metallic stents are effective in preventing acute occlusion and reducing late restenosis after coronary angioplasty, many concerns still remain. Compared with metallic stents, poly-l-lactic acid (PLLA) stents are biodegradable and can deliver drugs locally. The aim of this study was to evaluate the feasibility, safety, and efficacy of the PLLA stent. METHODS AND RESULTS Fi...
متن کاملHead-to-head comparison of a drug-free early programmed dismantling polylactic acid bioresorbable scaffold and a metallic stent in the porcine coronary artery: six-month angiography and optical coherence tomographic follow-up study.
BACKGROUND We aimed to evaluate a new drug-free fully bioresorbable lactic acid-based scaffold designed to allow early dismantling synchronized with artery wall healing in comparison with a bare metal stent (BMS). METHODS AND RESULTS Twenty-three BMS (3.0×12 mm) and 36 lactic acid-based bioresorbable scaffolds (BRS, 3.0×11 mm) were implanted in porcine coronary arteries. QCA and optical coher...
متن کاملComparison of acute thrombogenicity for metallic and polymeric bioabsorbable scaffolds in a porcine arteriovenous shunt model
number: Euro17A-OP0628 Abstract type: Oral Presentation Reference: This abstract was presented at EuroPCR 2017, 16-19 May 2017, Paris Link: https://abstractbook.pcronline.com/export/pdf/id/628 Published on: 16 May 2017 Comparison of acute thrombogenicity for metallic and polymeric bioabsorbable scaffolds in a porcine arteriovenous shunt model LIPINSKI M.(1)ACAMPADO , E.(2)CHENG , Q.(2)ADAMS , L...
متن کاملThrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.
BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012