Assessment of Eclipse electron Monte Carlo output prediction for various topologies

نویسندگان

  • Shane L. Lawrence
  • Natascha H.M. Van Lieshout
  • Paule M. Charland
چکیده

Monte Carlo simulation is deemed to be the leading algorithm for accurate dose calculation with electron beams. Patient anatomy (contours and tissue densities) as well as irradiation geometry is accounted for. The accuracy of the Monitor Unit (MU) determination is one essential aspect of a treatment planning system. Patient-specific quality assurance of a Monte Carlo plan usually involves verification of the MUs with an independent simpler calculation approach, in which flat geometry is to be assumed. The magnitude of the discrepancies between flat and varied surfaces for a few scenarios has been investigated in this study. The ability to predict MUs for various surface topologies by the commercial electron Monte Carlo implementation from Varian Eclipse system (Eclipse eMC) has been evaluated and compared to the Generalized Gaussian Pencil Beam (GGPB) algorithm. Ten phantoms with different topologies were constructed of water-equivalent material. Measurements with a parallel plate ionization chamber were performed using these phantoms to gauge their relative impact on outputs for 6, 9, 12, 16, and 20MeV electron beams from a Varian TrueBeam with cone sizes ranging from 6 × 6 cm2 to 25 × 25 cm2. The corresponding Monte Carlo simulations of the measured geometries were carried out using the CT scans of these phantoms. The results indicated that the Eclipse eMC algorithm can predict these output changes within 3% for most scenarios. However, at the lowest energy, the discrepancy was the greatest, up to 6%. In comparison, the Eclipse GGPB algorithm had much worse agreement, with discrepancies up to 17% at the lowest energies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

متن کامل

Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...

متن کامل

Loss of Load Expectation Assessment in Deregulated Power Systems Using Monte Carlo Simulation and Intelligent Systems

Deregulation policy has caused some changes in the concepts of power systems reliability assessment and enhancement. In this paper, generation reliability is considered, and a method for its assessment using intelligent systems is proposed. Also, because of power market and generators’ forced outages stochastic behavior, Monte Carlo Simulation is used for reliability evaluation. Generation r...

متن کامل

Assessment of Effect Technical Directional Bremsstrahlung Splitting (DBS) on Spectra and Parameters of Simulation with Monte carlo Method BEAMnrc Code (Study Monte Carlo)

Introduction: Previous studies have shown that a Monte Carlo method for the transportations photon beam in medical linear accelerator is a good way. Strip of simulation can be used to measure the dose distribution in phantoms and patients' body. EGSnrc Code is the only code written for use in the field of radiation therapy that has many subset codes that BEAMnrc code is an impo...

متن کامل

Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac

Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015