Cost-effectiveness of dual-chamber pacemaker therapy: does single lead VDD pacing reduce treatment costs of atrioventricular block?

نویسندگان

  • U K Wiegand
  • J Potratz
  • F Bode
  • R Schreiber
  • H Bonnemeier
  • W Peters
  • H A Katus
چکیده

AIMS Implantation of single-lead VDD pacemakers is an established alternative to DDD pacing in patients with atrioventricular block. This study compares the long-term costs of both systems. METHODS AND RESULTS Three hundred and sixty patients with atrioventricular block received VDD or DDD pacemakers in alternating order. Primary costs of implantation included: devices, leads and operation material, surgeons, nurses, medical technicians, and hospitalization. The mean cost of an uncomplicated DDD pacemaker implantation was defined as 1000 virtual cost-units (CU). Costs of pacemaker related complications or re-operations as well as upgrades from VDD to DDD devices were considered secondary costs and assessed during a mean follow-up period of 42+/-15 months. Pacing efficacy was assessed by event-free survival with maintained atrioventricular synchronized pacing mode. Costs of pacemaker devices were not different (639+/-26 CU in VDD vs 641+/-32 CU in DDD, ns). However, due to lower costs of lead hardware (102+/-10 CU in VDD vs 133+/-14 CU in DDD, P<0.001) and shorter implantation procedures (44.3+/-5.1 min vs 74.4+/-13.5 min, P<0.001), costs of an uncomplicated implantation were 8.9% lower in the VDD group (911+/-35 CU vs 1000+/-39 CU, P<0.001). A smaller complication rate in the VDD group led to a 16.1% reduction of secondary costs (26+/-17 CU year(-1)vs 31+/- 25 CU year(-1), P=0.024). Event-free survival did not differ between groups (83.4% in VDD vs 84.9% in DDD, ns). CONCLUSION Use of single-lead VDD pacemakers achieves significant reduction of implantation and follow-up costs without loss of therapeutic efficacy compared to conventional DDD systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?

BACKGROUND Dual chamber pacemakers (single chamber pacing dual chamber sensing cardiac pacemaker (VDD) and dual chamber pacing and sensing cardiac pacemaker (DDD)) are being used frequently in children and adolescents. The aim of this study was to verify the safety and performance of the VDD and DDD pacing systems, and to evaluate the differences between two pacing modes with regard to atrial s...

متن کامل

Stable Atrial Sensing on Long-Term Follow Up of VDD Pacemakers

BACKGROUND The hemodynamic advantages of maintaining AV synchrony through AV synchronous pacing are widely known as compared to single chamber pacing. DDD pacemaker implantation entails higher cost and is technically more challenging than the VDD pacemaker. METHODS Seventy one patients underwent VDD lead (Biotronik GmbH, St. Jude Medical and Medtronic Inc.) implantation at KEM hospital, Mumba...

متن کامل

Long-term outcome in patients receiving permanent pacemaker implantation for atrioventricular block

A permanent pacemaker (PPM) with dual chamber pacing (DDD) offers atrioventricular synchronization for patients with atrioventricular block (AVB). Single lead atrial synchronous ventricular pacing mode (VDD) is an alternative, but there are concerns about its efficacy and risk of atrial undersensing. Whether VDD can be a good alternative in patients with AVB remains unknown. The aim of the pres...

متن کامل

Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. ...

متن کامل

Predictors of loss of atrioventricular synchrony in single lead VDD pacing.

OBJECTIVE To evaluate maintenance of proper VDD function, defined as persistence of sinus rhythm with atrial synchronous ventricular pacing, and to define factors predicting failure of the VDD mode in patients with atrioventricular (AV) block and normal sinus function. DESIGN Observational study in 86 consecutive patients (mean (SD) age 74 (12) years; 38 women, 48 men) with single lead VDD pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2001